Left ventricular function and volumes from cardiac magnetic resonance and gated [13N]-ammonia positron emission tomography myocardial perfusion imaging in patients with ischemia with no obstructive coronary arteries: a prospective head-to-head comparison using hybrid positron emission tomography/magnetic resonance.

Runze Wen, Qiang Xie, Ming Ni, Bo Pan, Xingxing Zhu, Xueer Meng, Dan Li, Xuemei Wang

Department of Nuclear Medicine, The First Affiliated Hospital of University of Science and Technology of China (USTC), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China. · Department of Cardiovascular Medicine, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China.

Observational · n=75

Key points

From the paper's conclusion
  • LVEF and RWMS can be reliably and accurately quantified by ECG-gated 13N-ammonia PET, although LV volumes are systematically underestimated compared with those quantified by CMR. ECG-gated 13N-ammonia PET may serve as a complementary modality for the assessment of LV systolic function; however, CMR remains the benchmark for LV volumetric measurement and myocardial tissue assessment.

Abstract

BACKGROUND: Electrocardiogram (ECG)-gated 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI) has been widely validated for the assessment of left ventricular (LV) volumes and function. This study aimed to compare the accuracy of LV volumes and functional parameters derived from 13N-ammonia PET with those obtained by cardiac magnetic resonance (CMR), using CMR as the reference standard. METHODS: A total of 75 consecutive patients with known or suspected ischemia with no obstructive coronary arteries (INOCA) who simultaneously underwent ECG-gated 13N-ammonia PET and CMR using a hybrid PET/magnetic resonance (MR) scanner were enrolled in this prospective study. Left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), left ventricular stroke volume (LVSV), left ventricular ejection fraction (LVEF), and regional wall motion score (RWMS) were derived from both imaging modalities and compared using correlation and Bland-Altman (BA) analyses. Additionally, inter- and intraobserver variability in LV volumetric parameters and LVEF were evaluated for both imaging modalities. RESULTS: The correlation between PET and CMR was strong for LV volumes (r>0.83) and moderate for LVEF (r=0.65). The moderate LVEF correlation may be partially explained by the narrow range of LVEF values across the study cohort. Moreover, the agreement between 13N-ammonia PET and CMR for LVEF was good, with minimal bias (-0.57%); however, 13N-ammonia PET systematically underestimated LV volumes, with negative biases for LVEDV (-7.76 mL), LVESV (-3.28 mL), and LVSV (-5.33 mL). Similar, strong correlations and good agreement were observed in patients with reduced myocardial flow reserve (MFR). For both PET and CMR, inter- and intraobserver agreement for LV volumes and LVEF was high and comparable between the two modalities. In addition, RWMSs derived from ECG-gated 13N-ammonia PET and CMR also exhibited good agreement (kappa =0.84±0.02). CONCLUSIONS: LVEF and RWMS can be reliably and accurately quantified by ECG-gated 13N-ammonia PET, although LV volumes are systematically underestimated compared with those quantified by CMR. ECG-gated 13N-ammonia PET may serve as a complementary modality for the assessment of LV systolic function; however, CMR remains the benchmark for LV volumetric measurement and myocardial tissue assessment.