Multimodal Comparison of Left Ventricular Function and Volume Assessment Methods in Patients With Coronary Artery Disease: Echocardiography, Nuclear Myocardial Perfusion Imaging, and Cardiac Magnetic Resonance
Fanghu Wang, Xiaochun Zhang, Entao Liu, Xinchao Yao, Zeyin Xiang, Hui Yuan, Lei Jiang
Key points
From the paper's conclusion- Background To evaluate the correlations and agreement between echocardiography, nuclear myocardial perfusion imaging (MPI), and cardiac magnetic resonance (CMR) for assessing left ventricular (LV) function and volumes in patients with coronary artery disease (CAD).
Abstract
Background To evaluate the correlations and agreement between echocardiography, nuclear myocardial perfusion imaging (MPI), and cardiac magnetic resonance (CMR) for assessing left ventricular (LV) function and volumes in patients with coronary artery disease (CAD). Methods Forty‐eight patients with suspected or confirmed CAD who underwent echocardiography, nuclear MPI, and CMR within 1 week were included. The LV ejection fractions (EF), end‐diastolic volume (EDV), and end‐systolic volume (ESV) obtained using each modality were compared using correlational and Bland–Altman analyses, with CMR serving as the reference standard. Additionally, 13 N‐NH 3 and 99m Tc‐sestamibi ( 99m Tc‐MIBI) MPI subgroup analyses were conducted using CMR as the reference. Results Nuclear MPI showed better correlation and agreement with CMR than echocardiography for EF values ( r = 0.93 vs. 0.88; bias: −2.8% vs. 4.4%). For LV volumes, nuclear MPI and CMR showed excellent correlations (EDV/ESV: r = 0.94) with better ESV agreement (bias: −10.1 mL) than EDV (−25.4 mL). In subgroup analyses, 13 N‐NH 3 PET MPI maintained excellent correlations with CMR (EF: r = 0.95; EDV/ESV: r = 0.97), with minimal EF bias (−0.7%). 99m Tc‐MIBI SPECT MPI showed a greater EF bias (−7.8%) despite a good correlation ( r = 0.95) and wider limits of agreement for LV volumes (EDV: −92.3 to 47.4 mL; ESV: −66.0 to 61.7 mL). Conclusions 13 N‐NH 3 PET MPI demonstrates excellent correlation and agreement with CMR, providing a reliable alternative for assessing LV function and volumes in patients with CAD. Contrarily, echocardiography systematically overestimates EFs. These findings provide practical insights into discrepancies among imaging modalities and may support clinical decision‐making in CAD management.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Left ventricular function and volumes from cardiac magnetic resonance and gated [13N]-ammonia positron emission tomography myocardial perfusion imaging in patients with ischemia with no obstructive coronary arteries: a prospective head-to-head comparison using hybrid positron emission tomography/magnetic resonance.Quantitative imaging in medicine and surgery · 2026
- Stress myocardial perfusion imaging with photon-counting CT: Initial validation against reference modalitiesDiagnostic and Interventional Imaging · 2025
- Coronary volume-to-left ventricular mass ratio as a predictor of agreement between myocardial perfusion- and invasive fractional flow reserve measurementsEuropean Heart Journal · 2026
- Observer-Related Versus Cross-Modality Variability in Ventricular Quantification by Cardiac CT and Cardiovascular Magnetic Resonance.Diagnostics (Basel, Switzerland) · 2026
- Quantitative Assessment of Myocardial Perfusion: A Review of PET/CT and CMR Methods.JACC. Cardiovascular imaging · 2026
- Myocardial blood flow quantification by widely available conventional nai SPECT improves detection of hemodynamically significant coronary stenosisEuropean Heart Journal · 2026