Quantifying effective radiation doses from 13N-ammonia PET/CT procedures for myocardial perfusion imaging.
H Salah, M Alkhorayef, F Mayhoub, Essam Alkhaybari, N Abuhadi, Mayeen Uddin Khandaker, D A Bradley, Abdelmoneim Sulieman
INAYA Medical Collage, Nuclear Medicine Department, Riyadh, Saudi Arabia; College of Medical Radiologic Science, Sudan University of Science and Technology, Khartoum, Sudan. · Department of Radiological Sciences, College of Applied Medica l Sciences, King Saud University, P. O Bo x 10219, Riyadh, 11433, Saudi Arabia.
Key points
From the paper's conclusion- These results suggest that further dose-reduction strategies are warranted to mitigate radiation risks associated with this imaging modality.
Abstract
Positron emission tomography combined with computed tomography (PET/CT) is a useful hybrid imaging modality for the assessment and staging of diseases. PET/CT procedures using N-ammonia (13N-NH3) as a radiotracer are applied for measuring myocardial blood perfusion. The current study aimed to estimate patients' effective dose from internal and external exposure during myocardial perfusion PET/CT-13N-NH3 procedures. A total of 34 PET/CT procedures were performed using 13N-NH3 as the radiotracer. All procedures were conducted using a PET/CT Discovery 710 system (GE Healthcare) equipped with a 64-slice CT scanner. Patient demographics, administered activity, effective dose, and CT scan parameters (tube current-time product (mAs) and peak voltage (kVp)) were considered in this study. The mean and range of the tube current-time product (mAs) for the CT procedure were 28 (3-60). A constant X-ray tube potential of 120 kVp was used for all patients. Patient age (mean ± SD: 64 ± 11 years, range: 46-86) and body mass index (BMI) (mean ± SD: 33 ± 7 kg m-2, range: 19-52) were recorded. The mean administered activity of 13N-NH3 for rest and stress studies was 730 ± 40 MBq and 720 ± 50 MBq, respectively. The corresponding mean and range of effective doses (mSv) from internal and external exposure were 2.0 ± 0.1 (1.6-2.2) and 30 (8.2-42.4), respectively. Myocardial perfusion PET/CT with 13N-NH3 is associated with a relatively low effective dose compared to other radiotracers. While PET contributes to radiation exposure, CT is the dominant source. The average effective dose from CT was approximately 15 times higher than that from the PET procedure. Technologists often focus on optimizing the radiotracer rather than CT scan parameters. Optimization of CT scan parameters is therefore essential to minimize patient dose without compromising image quality. These results suggest that further dose-reduction strategies are warranted to mitigate radiation risks associated with this imaging modality.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multicenter Evaluation of Myocardial Flow Reserve as a Prognostic Marker for Mortality in¹³ N-Ammonia PET Myocardial Perfusion ImagingCirculation Cardiovascular Imaging · 2026
- The Effect of Motion Correction on Quantitative Perfusion Indices and Threshold-Based Interpretation in 13N-Ammonia Dynamic PET Myocardial Perfusion Imaging.Diagnostics (Basel, Switzerland) · 2026
- Left ventricular function and volumes from cardiac magnetic resonance and gated [13N]-ammonia positron emission tomography myocardial perfusion imaging in patients with ischemia with no obstructive coronary arteries: a prospective head-to-head comparison using hybrid positron emission tomography/magnetic resonance.Quantitative imaging in medicine and surgery · 2026
- Reduced papillary muscle uptake on stress 13N-ammonia PET is associated with higher myocardial flow reserve and may reflect relative tracer distribution.Nuclear medicine communications · 2026
- Cardiac PET Imaging in Coronary Artery Disease: Myocardial Perfusion and Flow Reserve Assessment.Radiologic clinics of North America · 2026
- Association between PET-derived ischemic burden and cardiopulmonary functional gain after CTO revascularizationEuropean Heart Journal · 2026