Automatic transesophageal echocardiographic evaluation of patients with mitral valve prolapse: comparison with patients without structural cardiac chamber remodeling (an exploratory study).
Marcelo Luiz Campos Vieira, Ana C T Rodrigues, Edgar Daminello, Adriana Reche, Gustavo P de Almeida, Alessandra J Oliveira, Luiz O A Santos, Rafael B Piveta,
Department of Cardiology, Hospital Israelita Albert Einstein, São Paulo, SP, Brazil. · Department of Cardiology, São Paulo Federal University (UNIFESP), São Paulo, SP, Brazil.
Key points
From the paper's conclusion- Automatic mitral valve parameters differed significantly between patients with MVP and those without structural cardiac chamber remodeling. In exploratory analysis, patients in the upper range of ERO values (≥75th percentile) showed patterns involving posterior leaflet geometry that were consistent with the associations observed in continuous-variable analysis. These findings support the potential role of automated 3D assessment in the anatomical characterization of MVP.
Abstract
BACKGROUND: There is a paucity of information concerning automatic mitral valve apparatus (MVA) analysis of patients with mitral valve prolapse (MVP). We aimed to study with an automatic three-dimensional (3D) transesophageal echocardiography (TEE)-dedicated software, patients with moderate and severe mitral regurgitation when compared to patients with no structural cardiac chamber alterations [patients with patent foramen ovale (PFO) who underwent TEE]. METHODS: We employed TEE software dedicated to automatic analysis of 34 parameters of the MVA, comparing MVP patients with moderate and severe mitral regurgitation and patients with PFO without cardiac chamber structural alterations. Mitral valve effective regurgitant orifice (ERO) and regurgitant volume were correlated to automatic MVP parameters. RESULTS: Fifty-nine MVP patients and 43 PFO patients were analyzed. All MVP patients presented P2 MVP, 15 (25.4%) with both posterior and anterior prolapse. Twenty-seven automatic parameters (79%) were different concerning MVP and PFO patients (P<0.05): diameters, area, perimeter, height, angle, coaptation width, length, closure line length, and annulus. ERO was 0.43±0.11 cm2, and regurgitant volume was 62.9±14.9 mL/beat. Automatic analysis correlated to 75th percentile ERO MVP patients (ERO >0.48 cm2): posterior leaflet area (r=0.74, P=0.03); posterior leaflet length (r=0.73, P=0.03); tenting area (r=0.41, P=0.048). CONCLUSIONS: Automatic mitral valve parameters differed significantly between patients with MVP and those without structural cardiac chamber remodeling. In exploratory analysis, patients in the upper range of ERO values (≥75th percentile) showed patterns involving posterior leaflet geometry that were consistent with the associations observed in continuous-variable analysis. These findings support the potential role of automated 3D assessment in the anatomical characterization of MVP.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of circular and elliptical geometric models with optimal two-dimensional imaging view for Doppler quantification of mitral regurgitant volume in older patients.Frontiers in cardiovascular medicine · 2026
- Association between iatrogenic atrial septal shunt VTI and clinical outcomes after mitral transcatheter edge-to-edge repair.Frontiers in cardiovascular medicine · 2026
- Role of 3D TTE and TEE in predicting BMV outcomeEuropean Heart Journal Supplements · 2026
- Iatrogenic ASD gradient as a marker of residual mitral regurgitation severity after M-TEER procedureEuropean Heart Journal · 2026
- Left Ventricular Remodelling and Functional Status Across Mitral Regurgitation Severity in Mitral Valve ProlapsemedRxiv · 2026
- Three-Dimensional Transesophageal Echocardiographic Vena Contracta Area for Grading Mitral Regurgitation: Severity Cut-offs From a Prospective Tunisian Cohort.Echocardiography (Mount Kisco, N.Y.) · 2026