Role of 3D TTE and TEE in predicting BMV outcome
Asmaa Elbagoury, Hytham Soliman Ghareeb, Ashraf Ahmed, Mahmoud Elmallwany, Mohamed Ahmed Oraby, Khaled Elkhashab
Key points
From the paper's conclusion- These findings suggest that these 2-D TEE parameters can serve as valuable tools for anticipating the success of the targeted cardiac intervention.
Abstract
Background and Objectives The aim of this study is to find out quantitative morphological parameters that could be helpful in prediction of success and development of de novo or worsening MR after PBMV, and to define the role of 3D TEE in mitral valve assessment. Methods This prospective cohort study was conducted on 85 patients, age >18 years old, of both sexes, presented to (NHI) and Fayoum University hospital with isolated severe rheumatic MS with Wilkins' score <12, and nonexisting or mild mitral insufficiency; who then underwent PBMV in the period from August 2021 to May 2023. Exclusion criteria: Any contraindication or unfavorable clinical characteristics for PMV or for TEE. Results The ROC curve analysis revealed noteworthy insights into the predictive capabilities of the measured parameters. In the context of 2-D TEE measurements, the P/A LLR, CAR, and DH emerged as robust predictors of procedural success. The high Area Under the Curve (AUC) values for these parameters (0.931, 0.929, and 0.946, respectively) indicated their strong discriminatory power. Furthermore, the significant p-values (<0.001) underscored the statistical significance of these associations. These findings suggest that these 2-D TEE parameters can serve as valuable tools for anticipating the success of the targeted cardiac intervention. The 3-D TEE measurements also exhibited promising predictive potential. Notably, P/A LLR, CAR, and Ca score demonstrated varying levels of accuracy as predictors of procedural success. While all three parameters exhibited strong AUC values (0.929, 0.930, and 0.863, respectively), the significance of their associations (P < 0.001) emphasized their predictive relevance. These findings highlight Conclusions In conclusion, the study's findings underscore the potential of echocardiographic measurements as predictive markers for BMV procedural success. 3D TEE has added value over 2D TEE. The utility of 3-D TEE measurements is complementing the predictive capacity of 2-D TEE parameters.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Updated Wilkins Score Predicting Success of Balloon Mitral Valvuloplasty in Rheumatic Mitral StenosisJACC Asia · 2026
- Cardiac remodelling and clinical outcomes following surgical and transcatheter mitral valve interventionsEuropean Heart Journal · 2026
- Advanced and novel echocardiographic right ventricular function parameters predict outcomes after percutaneous mitral valve repairEuropean Heart Journal · 2026
- 6 months follow-up after mitral transcatheter edge-to-edge repair: clinical and procedural determinates that may affect residual mitral regurgitationEuropean Heart Journal · 2026
- Impaired 3D left atrial volumetric/ mechanical coupling index is related to unfavorable mitral remodeling and adverse clinical events in primary mitral regurgitationEuropean Heart Journal · 2026
- Reverse cardiac remodeling after transcatheter edge-to-edge repair for primary mitral regurgitation: a cardiac magnetic resonance studyEuropean Heart Journal · 2026