Iatrogenic ASD gradient as a marker of residual mitral regurgitation severity after M-TEER procedure
A Kalompatsou, I Kachrimanidis, Y Dimitroglou, D Tsartsalis, C L Ververeli, S Tsalamandris, K Aznaouridis, K Dimitriadis,
Key points
From the paper's conclusion- Conclusion The iASD gradient is associated with residual mitral regurgitation severity and shows good diagnostic accuracy for detecting 3D-VCA >0.2 cm².
Abstract
Introduction Assessment of procedural success following transcatheter mitral edge-to-edge repair (M-TEER), including non-invasive parameters, remains challenging. Purpose The association between iatrogenic atrial septal defect (iASD) gradient and post-procedural three-dimensional vena contracta area (3D-VCA) as a marker of residual mitral regurgitation severity has not been clearly defined. Methods In this prospective study, 26 patients who underwent M-TEER at a tertiary cardiovascular center were analyzed over the past year. Median age was 78 years (IQR 74–81.2), and 80.7% were male. Secondary mitral regurgitation was present in 50%, primary in 34.6%, and mixed etiology in 15.3%. The median post-procedural transmitral valve gradient was 2 mmHg (IQR 2–3), assessed by transesophageal echocardiography. Continuous-wave Doppler recordings across the iASD were obtained intraoperatively immediately after catheter withdrawal from the left atrium. The largest systolic 3D-VCA was quantified by direct planimetry from en face short-axis views using multiplanar reconstruction. Patients were stratified according to post-procedural 3D-VCA (≤0.2 vs >0.2, cm2). Diagnostic accuracy of the iASD gradient for identifying 3D-VCA >0.2cm2 was assessed using receiver operating characteristic (ROC) curve analysis, with optimal cutoff determined by the Youden index. Results Patients with post-procedural 3D-VCA >0.2 cm² demonstrated significantly higher iASD gradients than those with 3D-VCA ≤0.2 cm² (5.64±2.84 vs 3.07±1.10 mmHg, p=0.007). ROC analysis demonstrated good discriminatory ability for identifying 3D-VCA >0.2cm2 (AUC 0.81, 95% CI 0.61–0.97). An optimal iASD cutoff gradient ≥5 mmHg yielded a sensitivity of 63.6% and specificity of 93.3% for predicting 3D-VCA >0.2 cm². Conclusion The iASD gradient is associated with residual mitral regurgitation severity and shows good diagnostic accuracy for detecting 3D-VCA >0.2 cm². An iASD gradient ≥5 mmHg may serve as a simple and highly specific marker for immediate post-procedural assessment after M-TEER; however, validation in larger cohorts is required.Violin PlotFor image description, please refer to the figure legend and surrounding text.ROC curveFor image description, please refer to the figure legend and surrounding text.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association between iatrogenic atrial septal shunt VTI and clinical outcomes after mitral transcatheter edge-to-edge repair.Frontiers in cardiovascular medicine · 2026
- 6 months follow-up after mitral transcatheter edge-to-edge repair: clinical and procedural determinates that may affect residual mitral regurgitationEuropean Heart Journal · 2026
- Outcomes of transcatheter edge-to-edge repair for moderate mitral regurgitationEuropean Heart Journal · 2026
- Using Transmitral Pressure Gradients and Residual Mitral Regurgitation to Optimize Outcome After Transcatheter Edge-to-Edge RepairJournal of the American College of Cardiology · 2025
- High procedural success despite limited prognostic value of acute haemodynamics after TEEREuropean Heart Journal · 2026
- Initial Clip Selection and Outcomes After Mitral Transcatheter Edge-to-Edge Repair: A Single-Center Experience.Journal of clinical medicine · 2026