Percutaneous balloon valvuloplasty in a small cat with pulmonary valve stenosis and concomitant tricuspid valve dysplasia.
H M Hipp, N Schreiber, M L Wieser, N Pereira, M Baron Toaldo
Divison of Cardiology, Clinic for Small Animal Internal Medicine, Vetsuisse Faculty, University of Zurich, Switzerland. · Section of Anaesthesiology, Department of Clinical Diagnostics and Services, Vetsuisse Faculty, University of Zurich, Switzerland.
Key points
From the paper's conclusion- A 14-month-old, male castrated, 3,9-kg Singapura cat was referred for treatment of severe pulmonary valve stenosis associated with tricuspid valve dysplasia.
Abstract
A 14-month-old, male castrated, 3,9-kg Singapura cat was referred for treatment of severe pulmonary valve stenosis associated with tricuspid valve dysplasia. The cat was pretreated with atenolol and scheduled for pulmonary balloon valvuloplasty. Because the right femoral vein could not accommodate a 5 Fr introducer, vascular access was obtained via the left external jugular vein, followed by right ventricular catheterisation, pressure measurement and angiography. A 10 mm low pressure balloon catheter was advanced over a guidewire to the level of the pulmonary valve and inflated once, resulting in complete loss of the balloon waist. During the procedure, the cat was severely hypotensive for 30 minutes, lasting from the time of ca-theterisation of the right ventricular outflow tract until nearly the end of anaesthesia. Postoperative tachypnoea was attributed to congestive heart failure, although aspiration pneumonia could not be excluded. The patient was discharged the day after the intervention following a single dose of furosemide and received amoxicillin-clavulanate for ten days. Echocardiography after eleven days, three months and 16 months demonstrated a marked and sustained reduction of the transvalvular pressure gradient. The cat showed an improved activity level after the procedure, which persisted over the 16-month follow-up period.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-pressure balloon valvuloplasty in small dogs with severe pulmonary stenosis: retrospective evaluation of the Mustang™ Balloon Dilatation Catheter in 12 dogs.Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology · 2026
- Echocardiographic description of pulmonary vein stenosis in a cat with atrioventricular septal defect.JFMS open reports · 2026
- Incidence of Infective Endocarditis in Dogs After Balloon Dilatation of Congenital Pulmonic Stenosis Without Peri- and Postoperative Antimicrobial Prophylaxis.Animals : an open access journal from MDPI · 2026
- Peripheral pulmonary arterial stenosis due to lung tumor in a cat.The Journal of veterinary medical science · 2026
- Case Report: Steerable catheter- and balloon-assisted recapture of a self-expanding pulmonary valve: a novel technical solutionFrontiers in Cardiovascular Medicine · 2026
- Multicenter, retrospective study of balloon valvuloplasty-associated pulmonary artery dissection in dogs with pulmonary valve stenosis.Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology · 2026