M E McMullen, R L Winter, K L Maneval, C S Ferrel
The use of the Mustang™ balloon catheter for BV is feasible in small dogs and may provide benefit in those with severe type B or intermediate-type PS.
INTRODUCTION/OBJECTIVES: Balloon valvuloplasty (BV) is a common treatment in dogs with severe valvar pulmonary stenosis (PS). Many reports in dogs with PS describe low-pressure balloon catheter use, with successful outcomes expected with type A. High-pressure balloon catheter use in dogs with type B PS has been reported; however, these reports typically describe dogs of larger body weight. The Mustang™ Balloon Dilatation Catheter, which requires smaller introducer sheath sizes, may be of use in small dogs with PS. The objective of this study was to retrospectively evaluate the immediate outcomes of dogs with severe PS that underwent BV with a Mustang™ balloon catheter.
ANIMALS, MATERIALS AND METHODS: Twelve client-owned dogs with type B or intermediate-type PS that underwent BV were included in the study. Medical records, echocardiographic images, and angiographic examinations were reviewed. Maximal pressure gradient across the pulmonary valve was assessed before and 18-24 h after BV. Intra-operative complications, introducer size, and size of balloon catheter used were recorded.
RESULTS: The median (range) weight at the time of BV was 3.05 kg (2.2-5.7 kg). A 6-Fr introducer was used in 10 of 12 dogs. The median (standard deviation) pulmonary annulus diameter was 7.0 ± 1.09 mm, and the balloon-to-annulus ratio was 1.4 ± 0.09. Pulmonary pressure gradient decreased from 168 ± 46 mmHg to 56 ± 25 mmHg (P<0.0001).
STUDY LIMITATIONS: Limitations include the retrospective nature of the study, the small number of dogs, and the reporting of only immediate outcomes.
CONCLUSIONS: The use of the Mustang™ balloon catheter for BV is feasible in small dogs and may provide benefit in those with severe type B or intermediate-type PS.