A novel technique for in vitro assessment of marginal fit in full-arch implant-supported prostheses.
Thaís Barbin, Letícia Del Rio Silva, Daniele Valente Velôso, Anna Gabriella Camacho Presotto, Valentim Adelino Ricardo Barão, Marcelo Ferraz Mesquita, Guilherme Almeida Borges
Universidade Estadual de Campinas - Unicamp, Piracicaba Dental School, Department of Prosthodontics and Periodontology, Piracicaba, SP, Brazil. · Universidade de São Paulo - USP, School of Dentistry, Department of Prosthodontics, São Paulo, SP, Brazil.
Key points
From the paper's conclusion- The NS technique yielded lower vertical marginal fit values than the SS technique, regardless of the framework material, suggesting that it may reflect the marginal fit of the framework in the absence of screw-induced preload.
Abstract
This study proposes a novel no-screw (NS) technique for assessing marginal fit, comparing its performance with the established single-screw (SS) protocol, also known as the Sheffield test. Four implants and their corresponding abutments were placed in prototyped maxillae. Screw-retained implant-supported frameworks were fabricated from cobalt-chromium (Co-Cr) and titanium alloy containing 6% aluminum and 4% vanadium (Ti) using computer-aided design-computer-aided manufacturing (CAD-CAM) milling technology. Marginal fits were measured using the SS and NS techniques (n = 5 per group). For the NS technique, each framework was placed in the prototyped maxillae and fixed to the mesial side of the four abutments using a liquid-powder technique without screws. Both techniques (SS and NS) were performed 3 times for each framework, and the mean value was calculated. Data were analyzed using two-way analysis of variance (ANOVA) followed by Bonferroni's test. There was no interaction between technique and material (p = 0.321). However, pooling techniques and materials significantly influenced fit values (p < 0.01). Fit values were lower for the NS technique (41.41 ± 12.46 µm) than for the SS test (97.63 ± 32.13 µm), regardless of material (p = 0.003). Lower fit values were observed for Ti (54.69 ± 34.36 µm) than for Co-Cr (84.35 ± 35.70 µm), regardless of the technique used (p = 0.01). The NS technique yielded lower vertical marginal fit values than the SS technique, regardless of the framework material, suggesting that it may reflect the marginal fit of the framework in the absence of screw-induced preload.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of scanner type and prosthesis design-luting protocol combinations on the passive fit of interim implant-supported complete-arch fixed dental prostheses.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Accuracy of removable partial denture frameworks fabricated by selective laser melting and conventional casting techniques: A systematic review and meta-analysis.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- In Vivo Assessment of Complete-Arch Implant Impressions Using a Clinical Seating Score: A Proof-of-Principle Case Report.Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] · 2026
- Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete-Arch Implant Prostheses: A Pilot Randomized Controlled Trial.Clinical oral implants research · 2026
- Interimplant distance and angulation measurement from CAD-generated multiunit abutment interfaces: A scan body-independent technique.The Journal of prosthetic dentistry · 2026
- Clinical and Finite Element Evaluation of Fixed Implant Prosthesis Designs for the Edentulous MandibleClinical Implant Dentistry and Related Research · 2026