Clinical oral implants research

Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete-Arch Implant Prostheses: A Pilot Randomized Controlled Trial.

Zhuo-Li Huang, Xiao-Jiao Fu, Chen Sun, Shu-Jiao Qian, Hong-Chang Lai, Bei-Lei Liu, Jun-Yu Shi

Department of Oral and Maxillofacial Implantology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, China.

Randomised · n=17

Key points

From the paper's conclusion
  • Objectives To compare the passive fit, accuracy discrepancy, patient‐reported outcomes, and operator assessment between intraoral photogrammetry (IPG) and conventional impression (CI) for complete‐arch implant‐supported prostheses.

Abstract

OBJECTIVES: To compare the passive fit, accuracy discrepancy, patient-reported outcomes, and operator assessment between intraoral photogrammetry (IPG) and conventional impression (CI) for complete-arch implant-supported prostheses. MATERIALS AND METHODS: Patients requiring complete-arch implant-supported prostheses were recruited. Each arch received both IPG and CI and was randomly assigned to one of two groups; a titanium framework was fabricated accordingly. The primary outcome was the passive fit of the framework. Secondary outcomes included accuracy discrepancies (RMS errors, distance errors, angle errors), patient-reported outcomes, and operator assessments. RESULTS: A total of 26 arches (13 in each group) from 17 patients were included. IPG was non-inferior to CI for passive fit score (adjusted between-group difference: 95% CI, -0.74-0.55; p = 0.003), including alternate finger pressure test (0/13 vs. 0/13), Sheffield test (4/13 vs. 5/13), marginal fit with all screws tightened (1/13 vs. 0/13), panoramic radiographic assessment (4/13 vs. 2/13), and screw resistance test (1/13 vs. 2/13). The RMS error, distance deviations, and angle deviation between IPG and CI were 31.50 ± 10.36 μm, 41.90 μm (IQR: 50.00 μm), and 0.19° (IQR: 0.24°), respectively. Patients rated IPG greater comfort (p = 0.035), lower anxiety (p = 0.005), and less nausea (p = 0.017). Operators reported less interference from patient reactions (p = 0.020) and greater fluency (p = 0.035) with IPG. CONCLUSION: Within the limitations of the present study, IPG achieved non-inferior passive fit with CI with clinically acceptable accuracy, superior patient comfort, and fewer operator disturbances, supporting its use as an alternative for complete-arch implant impressions. TRIAL REGISTRATION: ClinicalTrials.gov, NCT07190820.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete-Arch Implant Prostheses: A Pilot Randomized Controlled Trial — Science Skim