Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete-Arch Implant Prostheses: A Pilot Randomized Controlled Trial.
Zhuo-Li Huang, Xiao-Jiao Fu, Chen Sun, Shu-Jiao Qian, Hong-Chang Lai, Bei-Lei Liu, Jun-Yu Shi
Department of Oral and Maxillofacial Implantology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, China.
Key points
From the paper's conclusion- Objectives To compare the passive fit, accuracy discrepancy, patient‐reported outcomes, and operator assessment between intraoral photogrammetry (IPG) and conventional impression (CI) for complete‐arch implant‐supported prostheses.
Abstract
OBJECTIVES: To compare the passive fit, accuracy discrepancy, patient-reported outcomes, and operator assessment between intraoral photogrammetry (IPG) and conventional impression (CI) for complete-arch implant-supported prostheses. MATERIALS AND METHODS: Patients requiring complete-arch implant-supported prostheses were recruited. Each arch received both IPG and CI and was randomly assigned to one of two groups; a titanium framework was fabricated accordingly. The primary outcome was the passive fit of the framework. Secondary outcomes included accuracy discrepancies (RMS errors, distance errors, angle errors), patient-reported outcomes, and operator assessments. RESULTS: A total of 26 arches (13 in each group) from 17 patients were included. IPG was non-inferior to CI for passive fit score (adjusted between-group difference: 95% CI, -0.74-0.55; p = 0.003), including alternate finger pressure test (0/13 vs. 0/13), Sheffield test (4/13 vs. 5/13), marginal fit with all screws tightened (1/13 vs. 0/13), panoramic radiographic assessment (4/13 vs. 2/13), and screw resistance test (1/13 vs. 2/13). The RMS error, distance deviations, and angle deviation between IPG and CI were 31.50 ± 10.36 μm, 41.90 μm (IQR: 50.00 μm), and 0.19° (IQR: 0.24°), respectively. Patients rated IPG greater comfort (p = 0.035), lower anxiety (p = 0.005), and less nausea (p = 0.017). Operators reported less interference from patient reactions (p = 0.020) and greater fluency (p = 0.035) with IPG. CONCLUSION: Within the limitations of the present study, IPG achieved non-inferior passive fit with CI with clinically acceptable accuracy, superior patient comfort, and fewer operator disturbances, supporting its use as an alternative for complete-arch implant impressions. TRIAL REGISTRATION: ClinicalTrials.gov, NCT07190820.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of 12 Intraoral Scanners and Photogrammetric Systems for Full-Arch Edentulous Maxillae: An In Vitro Study.The International journal of periodontics & restorative dentistry · 2026
- Accuracy of complete-arch implant scans obtained using intraoral photogrammetry and a mobile-phone based photogrammetry system (T-Marker): A randomized crossover clinical study.Journal of dentistry · 2026
- Virtual-fit assessment of full-arch implant photogrammetry accuracy in a human cadaver modelJournal of Dentistry · 2026
- In Vivo Complete Arch Implant Impressions: Comparison of the Linear Precision of Digital and Conventional TechniquesInternational Dental Journal · 2026
- Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan-body for full-arch implants.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Trueness of extraoral photogrammetry, intraoral photogrammetry and direct intraoral scanning in the full-arch digital implant impression: a comparative in vitro studyJournal of Dentistry · 2025