Brazilian dental journal

Dental implants near internally resorpted roots: comparison between CBCT exam and periapical radiography.

Débora Costa Ruiz, Maria Fernanda Silva Andrade-Bortoletto, Sergio Lins de-Azevedo-Vaz, Deborah Queiroz Freitas

Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil. · Department of Dental Clinic, Federal University of Espírito Santo, Vitória, ES, Brazil.

Key points

From the paper's conclusion
  • Therefore, when periapical radiography is insufficient to establish a diagnosis, the use of CBCT may be clinically justified despite the additional radiation exposure.

Abstract

This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) and periapical radiography for detecting internal root resorption (IRR) in teeth adjacent to titanium or zirconia implants. Twenty single-rooted teeth (10 with IRR and 10 without) were individually placed in a human mandible. Periapical radiographs and CBCT exams were obtained with and without a titanium or zirconia implant. Radiographs were acquired with a photostimulable phosphor plate receptor at 70 kVp, 7 mA, and 0.160 s. CBCT scans were acquired at 90 kVp, 8 mA, 0.085mm3 voxel size, and 5×5cm field of view. Four examiners independently evaluated the radiographs and the CBCT exams. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity values were calculated and compared using two-way ANOVA (α = 5%). Inter- and intraexaminer agreement for IRR diagnosis was assessed using weighted Kappa. CBCT demonstrated significantly higher AUC (p=0.007), sensitivity (p=0.009), and specificity (p=0.037) for IRR detection compared with periapical radiographs, regardless of implant presence or type. The presence of an implant did not influence the results. Intraexaminer agreement ranged from moderate to almost perfect (0.48-0.95), and interexaminer agreement ranged from fair to almost perfect (0.30-0.85). CBCT demonstrated higher diagnostic accuracy than periapical radiography for detecting IRR, even in the presence of adjacent titanium or zirconia implants, as implant-related artifacts did not impair image interpretation. Therefore, when periapical radiography is insufficient to establish a diagnosis, the use of CBCT may be clinically justified despite the additional radiation exposure.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers