Frontiers in dental medicine

Diagnostic accuracy of CBCT versus digital radiography for early detection of peri-implant bone loss: a retrospective study with threshold and observer variability analysis.

Eman Aljoghaiman

Preventive Dental Science Department, Periodontics Division, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Eastern Province, Saudi Arabia.

Observational · n=100

Key points

From the paper's conclusion
  • CBCT was associated with higher odds of correct classification than digital periapical radiography (adjusted OR = 1.97, 95% CI: 1.16–3.34; p = 0.012).

Abstract

BACKGROUND: Early peri-implant marginal bone loss is clinically important. Digital periapical radiography is routinely used but may have limited sensitivity for subtle osseous changes, whereas CBCT provides three-dimensional visualization. OBJECTIVE: To compare CBCT and digital periapical radiography for detecting peri-implant marginal bone loss and evaluate severity-specific sensitivity, observer agreement, and repeatability. METHODS: This retrospective diagnostic accuracy study included 130 implant sites from 100 patients evaluated between January 2018 and December 2025. Three observers independently assessed both modalities. The reference standard classified 73 sites as positive, 55 as negative, and 2 as inconclusive. Binary diagnostic accuracy was based on site-level majority voting (≥2 of 3 observers), while the mean continuous bone-loss measurement across observers was used for primary ROC analysis. Severity-specific sensitivity was assessed for ≤0.5 mm, >0.5-1 mm, and >1 mm bone loss. Interobserver agreement and intraobserver repeatability were evaluated. Patient-clustered generalized estimating equation (GEE) logistic regression accounted for within-patient clustering and repeated observer assessments. RESULTS: Among 128 evaluable sites, CBCT demonstrated higher sensitivity (97.3% vs. 78.1%) and accuracy (96.9% vs. 87.5%) than digital periapical radiography. Specificity, PPV, and NPV were 96.4%, 97.3%, and 96.4% for CBCT vs. 100.0%, 100.0%, and 77.5%, respectively. AUCs were 0.91 vs. 0.78 (DeLong p < 0.001). CBCT sensitivity was 100.0%, 95.0%, and 100.0% across predefined severity categories vs. 46.7%, 80.0%, and 100.0% for digital periapical radiography. Interobserver agreement (κ = 0.85 vs. 0.67) and intraobserver repeatability (ICC = 0.93 vs. 0.77) were higher with CBCT. CBCT was associated with higher odds of correct classification than digital periapical radiography (adjusted OR = 1.97, 95% CI: 1.16-3.34; p = 0.012). CONCLUSION: CBCT showed superior diagnostic performance, particularly for smaller bone-loss lesions. However, radiographic changes of ≤0.5 mm should not be considered definitive evidence of biologically meaningful progression. CBCT should not be used for routine screening of asymptomatic implant sites but considered selectively when clinically justified. Prospective longitudinal studies are warranted.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers