Comparison between dual-angle periapical technique and cone-beam computed tomography in the identification of a second canal in mandibular incisors in the presence of a zirconia implant: An in vitro study.
Maria Fernanda Silva Andrade-Bortoletto, Fernanda Rodrigues de Oliveira, Thaísa Pinheiro Silva, Marcela Tarosso Réa, Renata Maira de Souza Leal, Débora Costa Ruiz, Deborah Queiroz Freitas
Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, Brazil. · Department of Restorative Dentistry, Federal University of Paraná, Curitiba, Brazil.
Key points
From the paper's conclusion- DPT and both CBCT protocols showed comparable diagnostic accuracy of the second canal regardless of zirconia implant presence.
Abstract
PURPOSE: To compare the accuracy of the dual-angle periapical technique (DPT) and CBCT acquired with two protocols in identifying lower incisors with a second canal adjacent to a zirconia implant. MATERIALS AND METHODS: Twenty single-rooted lower incisors were used, twelve with one canal and eight with two canals, confirmed with micro-CT. These roots and a zirconia implant were positioned in the alveolus of the mandibular right and left central incisors of a dry human mandible, respectively. Periapical radiographs were obtained using a Focus X-ray unit and a photostimulated phosphor plate (VistaScan system) with parameters of 70 kVp, 7 mA, and 0.125 seconds of exposure time. For each root, one standard and one with the tube shifted distally in 30°, with and without implant, totaling 80 radiographs. In addition, 80 CBCT scans were obtained with the OP300 Maxio (FOV 5×5 cm, 90 kVp), with and without implants, for each root. The variable parameters were: low-resolution (LR) (5 mA, 0.2 mm voxel) and high-resolution (HR) (10 mA, 0.085 mm voxel). Five evaluators assessed all images using a 5-point confidence scale. Two-way ANOVA with Sidak's post hoc test was used (P<0.05). Intra- and inter-examiner agreement were assessed with weighted kappa coefficients. RESULTS: DPT and both CBCT protocols(LR and HR) showed comparable AUC, sensitivity, and specificity (P>0.05). DPT and both CBCT protocols presented AUC, sensitivity, and specificity unaffected by the implant(P>0.05). CONCLUSION: DPT and both CBCT protocols showed comparable diagnostic accuracy of the second canal regardless of zirconia implant presence.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic accuracy of three CBCT protocols and Metal Artifact Reduction tool for detecting the second canal of mandibular incisors adjacent to a zirconia implant.Dento maxillo facial radiology · 2026
- Dental implants near internally resorpted roots: comparison between CBCT exam and periapical radiography.Brazilian dental journal · 2026
- Accuracy of panoramic radiography, periapical radiography, and CBCT in diagnosing apical root resorption.Brazilian oral research · 2026
- Diagnostic Accuracy of Cone-Beam Computed Tomography vs Panoramic Radiography in the Detection of Root Resorption: A Systematic Review of Clinical Studies.International dental journal · 2026
- Diagnostic accuracy of cone beam computed tomography in the detection of furcation perforations: an in vitro comparison with periapical radiography and micro-computed tomography.BMC oral health · 2026
- Root and root canal morphology of mandibular anterior teeth in a Jordanian subpopulation: a cross-sectional cone-beam computed tomography studyBMC Oral Health · 2026