Evaluating Reconstruction Methods for Biomedical Signals from Smart Devices
Daniel Rau, Mohammad Yahya, Jürgen Götze
Key points
From the paper's conclusion- Conclusion: Cubic spline interpolation and GPR provide robust, low-complexity solutions for biomedical signal reconstruction in telemedical scenarios, enabling reliable analysis even under aggressive sampling reduction.
Abstract
Introduction: Continuous monitoring with wearables often yields incomplete biomedical time series because of noise, sensor drop-outs or transmission errors. Reliable reconstruction of the missing information - especially respiratory- and cardiac-waveform morphology - is crucial for downstream clinical interpretation. Methods: Three reconstruction techniques (cubic spline interpolation, Gaussian Process Regression (GPR), autoregressive (AR) modeling) were evaluated on (i) simulated breathing-like signals generated with an undamped oscillator and (ii) real recordings from the piezoelectric VitaLog sensor. Down-sampling factors 1, 2, 4, 8, 16 and 32 simulate sparse sampling. Reconstruction quality was quantified by normalized RMSE percentage (pNRMSE) and the coefficient of determination r 2 . Results: Cubic spline interpolation and GPR consistently achieve pNRMSE > 97% and r 2 ~ 1.00, whereas AR degrades sharply for DF ≥ 16. Both spline and GPR recover periodic breathing patterns and artefact segments in biomedical piezoelectric data. Conclusion: Cubic spline interpolation and GPR provide robust, low-complexity solutions for biomedical signal reconstruction in telemedical scenarios, enabling reliable analysis even under aggressive sampling reduction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- reSPIRE: A wearable multimodal sensing system for monitoring ventilation, cardiovascular dynamics, and respiratory muscle activityBiosensors and Bioelectronics · 2026
- Reduction of Motion Artifacts in Cardiorespiratory Vital Signs as Oxygen Saturation and Non-Invasive Blood Pressure Through Redundant Denoising and Adaptive Filtering Methods for Wearable Healthcare Monitoring SystemsCardiovascular Engineering and Technology · 2026
- H ygieia : A Wearable Metamaterial Patch for Calibration-free Carotid Hemodynamics MonitoringProceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · 2026
- Noninvasive tracking of right ventricular systolic pressure via multi-channel digital auscultationEuropean Heart Journal · 2026
- Self-Supervised Representation Learning from Ventilator Waveforms: A Pilot Feasibility Study.Research square · 2026
- Robust synchronization of cardiac-linked biosensors under peak detection failures: a modality-agnostic approach via structural repair and Huber-IRLS regressionMeasurement Science and Technology · 2026