Measurement Science and Technology

Robust synchronization of cardiac-linked biosensors under peak detection failures: a modality-agnostic approach via structural repair and Huber-IRLS regression

Khaled Ben Abdessalem

Key points

From the paper's conclusion
  • We propose a robust interval-only synchronization pipeline comprising: (i) Dynamic Repair of abnormally short split intervals caused by extra (false) peaks; (ii) greedy peak-failure-aware mapping with q ∈ { 1 , 2 } to represent isolated missed beats as merged intervals; and (iii) Huber-iteratively reweighted least squares regression with median absolute deviation-based residual gating.

Abstract

Cooperative sensing in clinical instruments, distributed medical devices, and body-area networks requires accurate relative timing between independently clocked sensors, such as electrocardiography (ECG) and photoplethysmography (PPG). Interval-only synchronization operates directly on inter-beat intervals and avoids waveform alignment, but conventional estimators generally assume one-to-one reference–device beat correspondence. Missed beats, motion-induced false peaks, and gross interval errors violate this assumption by creating merged or split intervals and index shifts. We propose a robust interval-only synchronization pipeline comprising: (i) Dynamic Repair of abnormally short split intervals caused by extra (false) peaks; (ii) greedy peak-failure-aware mapping with q ∈ { 1 , 2 } to represent isolated missed beats as merged intervals; and (iii) Huber-iteratively reweighted least squares regression with median absolute deviation-based residual gating. Approximate uncertainty is quantified using an OLS-style Newey–West HAC covariance estimate (approximate and conditional when gating) and Fieller confidence sets for the ratio-defined delay-dynamics parameter. Monte Carlo ablation on synthetic ECG/PPG data (ORACLE and SIGNAL pipelines) shows that structural peak-detection failures can be catastrophic for OLS (e.g. RMS E after , all ≈ 227 ms under Extra 10% and ≈ 232 ms under a mixed extreme regime). In contrast, the proposed pipeline maintains robustness; in the mixed extreme regime it achieves RMS E after , in ≈ 37.4 ms (SIGNAL) and ≈35.9 ms (ORACLE). The real-data experiment was performed as a semi-synthetic feasibility validation using matched ECG/PPG beats from a real recording, with known clock skew imposed on the PPG timestamps and controlled peak failures injected into the resulting device interval sequence.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers