Development of a Controlled Pneumatically Actuated Lung Phantom for Surgical Simulation Support and Collapse Modeling
Chao Li, Maria Francesca Spadea, Domenico Riggio
Key points
From the paper's conclusion- The proposed phantom provides a reproducible platform for pressure-based investigation of lung collapse and may support thoracic surgical simulation.
Abstract
Lung collapse is an essential step in thoracic surgery and artificial pneumothorax. It is governed by the interaction between alveolar pressure (Palv) and intrapleural pressure (Ppl), with transpulmonary pressure (Ptp) determining lung expansion and collapse. Although pleural pressurization provides the primary trigger, the evolution of is influenced by airway outflow as air leaves the lung, affecting lung deflation. A comparable situation occurs during singlelung ventilation in thoracic surgery, where one lung remains ventilated while the contralateral lung is isolated and collapses through airway outflow. This work presents a pneumatically actuated lung phantom for investigating pressure-driven lung inflation and collapse under controlled conditions. The system uses independent airway and pleural pressure pathways, enabling continuous measurement of Palv and Ppl and real-time calculation of Ptp. Two collapse configurations with identical pleural pressurization and different airway outflow conditions (active and passive) are investigated. The experiments show that lung collapse occurs as Ptp approaches zero and may progress further as Ptp becomes negative, while different airway outflow conditions produce distinct pressure-time trajectories. In the active outflow configuration, negative Ptp values are observed due to externally applied airway suction, resulting in accelerated lung deflation. The proposed phantom provides a reproducible platform for pressure-based investigation of lung collapse and may support thoracic surgical simulation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Pressure Behavior of a Digital Drainage System.Innovations (Philadelphia, Pa.) · 2026
- Phantom system for endotracheal tube cuff seal testing during mechanical ventilationMedical & Biological Engineering & Computing · 2026
- Biomechanical analysis of pneumothorax: tissue failure, computational simulation, and clinical translation.Frontiers in bioengineering and biotechnology · 2026
- Development and technical characterization of a biomimetic thorax simulator for regional intrapulmonary pressure measurement.Frontiers in bioengineering and biotechnology · 2026
- Cadaveric Model of Pneumothorax (the GASP model): A Realistic, Reusable and Cost-Effective Simulator for Chest Drainage Training.Journal of education & teaching in emergency medicine · 2026
- Inter‐Individual Variation in LUNG Mechanics Assessed by the Non‐Invasive PEEP ‐Step Method During Laparoscopic and Robotic Surgery Indicates Need for Individualized Ventilatory SettingsActa Anaesthesiologica Scandinavica · 2026