Characterizing Bladder Filling Physiology with Long-Axial-FOV Dynamic PET/CT
Varvara Kondratyeva, Lukas Förner, Kartikay Tehlan, Melina Wördehoff, Axel Rominger, Kuangyu Shi, Thomas Wendler
Key points
From the paper's conclusion- In 21 successfully segmented patients, bladder volume increased approximately linearly over time (R 2 = 0.94[0.88, 0.97]), while fractional anisotropy decreased (Spearman’s P= −0.86[−0.96,−0.61]), indicating a trend toward a more spherical bladder shape during filling.
Abstract
Bladder filling during dynamic long-axial field-of-view (FOV) [ 18 F]Fluorodeoxyglucose ( 18 [F]FDG) positron emission tomography (PET) imaging leads to motion-related misalignment between frames. As a first step toward this misalignment correction, we track urinary bladder expansion and frame-byframe shape changes. Starting from the final PET frame, our algorithm applies intensity normalization, distribution-based correction, and region growing to estimate bladder volume over time. Compared to automated multi-organ segmentation frameworks, namely TotalSegmentator and MOOSE, the proposed PET-based method provides more accurate and physiologically plausible segmentations. Using our final-frame masks as reference, Dice-Sorensen coefficients were 0.40 } 0.37 for TotalSegmentator and 0.70 } 0.26 for MOOSE. In 21 successfully segmented patients, bladder volume increased approximately linearly over time (R 2 = 0.94[0.88, 0.97]), while fractional anisotropy decreased (Spearman’s P= −0.86[−0.96,−0.61]), indicating a trend toward a more spherical bladder shape during filling. The bladder was typically no longer traceable at frame 40 (4-4.5 min post-injection).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantifying [18F]FDG Uptake in the Liver, Spleen, Aorta, Bone Marrow, and Superior Vena Cava Using TotalSegmentator on [18F]PET/CT Imaging.Diagnostics (Basel, Switzerland) · 2026
- Automated long axial field of view PET image processing and kinetic modelling with the TurBO toolboxEuropean Journal of Nuclear Medicine and Molecular Imaging · 2026
- A General-Purpose Adaptable Foundation Model for Total-Body PET Kinetic Modelling.ArXiv · 2026
- Automated patient-derived noise power spectrum estimation in abdominal CT: a preliminary validationBiomedical Physics & Engineering Express · 2026
- Automated Vascular Segmentation in PET Imaging: From Technical Feasibility to Clinical Readiness, a Hands-On Scoping Review.Bioengineering (Basel, Switzerland) · 2026
- Spectral analysis of dynamic long-axial-field-of-view PET studies: a flexible framework for whole-body multi-organ kinetic quantificationPhysics in Medicine & Biology · 2026