Analytical performance and clinical classification value of a novel sandwich immunoassay for total testosterone measurement in low-concentration and hemodialysis populations.
He Shi, Huimei Wei, Shuaiwei Han, Minjie Liu, Bingjie Shui, Jijuan Gao, Yu Luo, Huaying Zhang,
Department of Clinical Laboratory, Hangzhou Traditional Chinese Medicine Hospital Affiliated to Zhejiang Chinese Medical University, Hangzhou, China. · Shenzhen Mindray Bio-Medical Electronics Co. Ltd., Shenzhen, China.
Key points
From the paper's conclusion- Objectives To evaluate the analytical performance and clinical classification value of a novel sandwich testosterone immunoassay, particularly for biochemical testosterone elevation in women and deficiency in male hemodialysis patients, using LC–MS/MS as the reference method.
Abstract
OBJECTIVES: To evaluate the analytical performance and clinical classification value of a novel sandwich testosterone immunoassay, particularly for biochemical testosterone elevation in women and deficiency in male hemodialysis patients, using LC-MS/MS as the reference method. METHODS: A total of 387 residual clinical serum samples were compared using Mindray TESTO, Siemens TSTII, and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Among these, 226 had testosterone concentrations <1.0 ng/mL, and 133 reproductive-age women were evaluated for biochemical hyperandrogenism classification. An additional 119 hemodialysis samples (94 men, 25 women) were assessed, with the 94 men evaluated for biochemical testosterone deficiency classification. Analyses included Passing-Bablok regression, Bland-Altman analysis, and independent imprecision, linearity, and interference studies. RESULTS: The Mindray TESTO assay showed total CVs of 1.68-2.71 % and good linearity (r=0.9997). Cross-reactivity was generally low, although phenylbutazone produced biases exceeding ±10 %. Both immunoassays correlated strongly with LC-MS/MS, with Mindray TESTO showing higher correlation and narrower limits of agreement in low-concentration samples (r=0.9603 vs. 0.8920). In women of reproductive age, Mindray TESTO demonstrated higher sensitivity (88.89 vs. 11.11 %) and κ agreement (0.784 vs. 0.189) for biochemical hyperandrogenism classification. In male hemodialysis patients, it achieved higher accuracy (94.68 vs. 88.30 %) and κ agreement (0.838 vs. 0.680) for biochemical testosterone deficiency classification. The ROC AUCs did not differ significantly (0.966 vs. 0.956; p=0.2776). CONCLUSIONS: The novel sandwich immunoassay showed improved agreement with LC-MS/MS at low testosterone concentrations and favorable performance in classifying biochemical testosterone elevation and deficiency.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assay-dependent reclassification of biochemical hyperandrogenism in female androgen testing: CLIA versus LC-MS/MS under common clinical decision thresholds.Clinica chimica acta; international journal of clinical chemistry · 2026
- Application of the latest CLSI EP guidelines in light-initiated chemiluminescent assay for testosterone.Journal of medical biochemistry · 2026
- Analytical performance evaluation of the new double-antibody sandwich Mindray total vitamin D assay and comparison vs. liquid chromatography tandem mass spectrometry.Clinical chemistry and laboratory medicine · 2026
- A-149 Reduction of Unnecessary Free and Bioavailable Testosterone Orders Using a Reflex StrategyClinical Chemistry · 2026
- Preliminary analytical evaluation of the fully automated Cobas i601 LC-MS/MS system for steroid hormones and vitamin D in a clinical laboratory.Clinica chimica acta; international journal of clinical chemistry · 2026
- Analytical performance of a single epitope meta-sandwich total 25-hydroxyvitamin D immunoassay and establishment of reference intervals in a Chinese population.Annals of clinical biochemistry · 2026