Clinical Chemistry

A-149 Reduction of Unnecessary Free and Bioavailable Testosterone Orders Using a Reflex Strategy

Christopher Koch, Dennis Orton, Victoria Higgins, Michael Reid, Ashley Newbigging, Evan Hagen, Joshua Raizman

Key points

From the paper's conclusion
  • By quantifying the probability of low cFT or cBAT when TT exceeds the lower reference limit, reflex algorithms can be derived to substantially reduce unnecessary testing.

Abstract

Background Evaluation of testosterone concentration is central to the diagnosis of male hypogonadism, with total testosterone (TT) recommended as the first-line screen in most clinical guidelines. Measurement or calculation of free (FT) or bioavailable testosterone (BAT) are only recommended in select circumstances, particularly when abnormalities in sex hormone binding globulin (SHBG) concentration or function are suspected. Nonetheless, FT and BAT are frequently ordered alongside TT in routine practice, raising concerns regarding overutilization. In this study we optimized calculated FT (cFT) and calculated BAT (cBAT) reference intervals, evaluated cFT/cBAT utilization and clinical utility relative to TT, and defined TT thresholds at which reflexing to cFT/cBAT is most likely to provide further value. Methods TT/SHBG (immunoassay, Roche) and albumin (various platforms) data from adult male patients was extracted from the laboratory information system (N=81,023). Reference intervals for cFT/cBAT were established using RefineR after excluding duplicates, inpatients, non-morning collections, and patients with abnormal diabetes, sex hormone, or prostate markers (N=22,101). Logistic regression was used to model the probability of low cFT/cBAT as a function of continuous TT after excluding duplicates (N=45,977). Results cFT RIs decreased with age with optimal partitioning in 10-year bins. Logistic regression showed a strong inverse association between TT and odds of low cFT (slope = -1.14, odds ratio = 0.32 per 1 nmol/L (∼29 ng/dL) TT increase, p<2×10?¹6), where 1 nmol/L (∼29 ng/dL) decrease in TT approximately tripled the odds of low FT. TT results of =2.5 nmol/L (72 ng/dL) predicted low cFT with 95% probability, while >7.6 nmol/L (219 ng/dL) predicted normal FT, defining a reflex range of 2.5-7.5 nmol/L (∼72-218 ng/dL). In unfiltered data, 10.9% of FT results fell within this interval. cBAT showed similar patterns. Conclusion TT by immunoassay strongly predicted cFT and cBAT, indicating limited incremental diagnostic value from routine FT/BAT testing. By quantifying the probability of low cFT or cBAT when TT exceeds the lower reference limit, reflex algorithms can be derived to substantially reduce unnecessary testing.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers