Interval-specific likelihood ratios improve interpretation of antiphospholipid antibody testing across different analytical platforms.
Juan Irure-Ventura, Rafael Gálvez-Sánchez, Nerea Mota-Pérez, Rodrigo Cantera-Estefanía, Alejandra Comins-Boo, Ana Isabel Merino-Fernández, José Luis Hernández-Hernández, Víctor Manuel Martínez-Taboada,
Immunology Department, University Hospital Marqués de Valdecilla, Santander, Spain. · Immunopathology Group, Marqués de Valdecilla University Hospital-IDIVAL, Santander, Spain.
Key points
From the paper's conclusion- Automated platforms, including PMAT represent analytically robust and clinically reliable methodologies for aPL testing, and represent valid alternatives to conventional ELISA assays. Interval-specific LR interpretation provides clinically relevant probabilistic information beyond dichotomous cut-offs, and may improve laboratory-based risk stratification in APS across analytical platforms.
Abstract
OBJECTIVES: Antiphospholipid antibodies (aPL) are essential biomarkers for classification, diagnosis, and risk stratification of antiphospholipid syndrome (APS). Although automated analytical platforms, such as chemiluminescent immunoassay (CLIA), and particle-based multi-analyte technology (PMAT), are increasingly implemented in routine laboratories, uncertainty remains regarding their diagnostic performance and interpretation of quantitative antibody results. We compared ELISA, CLIA, and PMAT for aPL detection and evaluated clinical utility of interval-specific likelihood ratios (LRs). METHODS: In this retrospective single-center diagnostic accuracy study, 351 patients with APS (238 thrombotic and 113 obstetric APS) and 197 controls were included. IgG and IgM anticardiolipin (aCL) and anti-β2-glycoprotein I (aβ2GPI) antibodies were measured using ELISA, CLIA, and PMAT. Analytical agreement was assessed by correlation analysis, and diagnostic performance by ROC analysis. Interval-specific LRs were calculated using predefined specificity thresholds (90 %, 95 %, and ≥99 %). RESULTS: Strong correlations were observed among all analytical platforms (p<0.001), with the highest agreement found between CLIA and PMAT. Automated platforms showed higher positivity rates than ELISA, particularly for IgM isotypes. PMAT achieved the highest diagnostic accuracy in thrombotic APS for IgG aCL (0.810), IgG aβ2GPI (0.816), and IgM aβ2GPI (0.848). Increasing antibody concentrations were associated with progressively higher interval-specific LRs, especially at specificity thresholds ≥99 %. Diagnostic performance was lower in obstetric APS. CONCLUSIONS: Automated platforms, including PMAT represent analytically robust and clinically reliable methodologies for aPL testing, and represent valid alternatives to conventional ELISA assays. Interval-specific LR interpretation provides clinically relevant probabilistic information beyond dichotomous cut-offs, and may improve laboratory-based risk stratification in APS across analytical platforms.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of testing method and analyte on the diagnosis of antiphospholipid syndrome: a survey by the association of medical laboratory immunologists.Clinical chemistry and laboratory medicine · 2026
- Identifying diagnostic testing gaps for antiphospholipid syndrome within a single healthcare system.PloS one · 2026
- B-173 Impact of Cut-off Adjustment on Inter-Assay Agreement of Anti-Cardiolipin and Anti-ß2 Glycoprotein I IgG Across Three Automated Immunoassay PlatformsClinical Chemistry · 2026
- Appropriateness of antiphospholipid antibody testing and its impact on diagnostic yield and clinical outcomes: a multicentre cohort study.Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis · 2026
- Digital decision support using a phospholipid-dependent biomarker for early exclusion of negative cases in lupus anticoagulant diagnostics.NPJ digital medicine · 2026
- Performance Assessment of Staclot-LA Assay on Fully Automated Coagulation Analyser for Lupus Anticoagulant Testing Using Internal and External Quality Controls.International journal of laboratory hematology · 2026