Key points
From the paper's conclusion- The optimized biosensor achieves a sensitivity of 479.58 deg/RIU, figure of merit of 152.01, and quality factor of 167.86 RIU-1 at a wavelength of 633 nm, demonstrating the potential of the optimized architecture for sensitive refractive-index sensing relevant to future colorectal cancer biomarker detection.
Abstract
Colorectal cancer biomarkers including methylated SDC2 (mSDC2), methylated SEPT9 (mSEPT9), and carcinoembryonic antigen (CEA), are effective biomarkers for the early detection and monitoring of colorectal cancer. In this study, a high-performance surface plasmon resonance (SPR) biosensor incorporating MgF2 prism/CaTiO3/Cu/Al2O3/BP multilayers is designed to enhance light-matter interaction and improve sensing performance. The brute force algorithm is employed to optimize the sensor parameters. Also, design is systematically optimized and investigated by using TMM, FEM and FDTD simulations. The accuracy of ANN, ANFIS and RBFNN system models in predicting sensor responses is thoroughly validated. The optimized biosensor achieves a sensitivity of 479.58 deg/RIU, figure of merit of 152.01, and quality factor of 167.86 RIU-1 at a wavelength of 633 nm, demonstrating the potential of the optimized architecture for sensitive refractive-index sensing relevant to future colorectal cancer biomarker detection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Integration of computational optics and machine learning for optimized SPR-based carcinoembryonic antigen detectionBiomedical Optics Express · 2026
- Multilayer CaF2 Prism-Coupled Ag/Si3N4/Al2O3 SPR Biosensor for the Early Detection of Carcinoembryonic Antigen Biomarker: A Numerical Approach.Sensors (Basel, Switzerland) · 2026
- Performance enhancement of a prism-based label-free SPR biosensor using a Cu/Si3N4/Al2O3 multilayer structure for cancer detection.Nanoscale advances · 2026
- Surface Plasmon Resonance Analysis of Cancer‐Related Refractive Index Variations Using a MoTe₂ –Black Phosphorus–Cu Multilayer StructureSurface and Interface Analysis · 2026
- Performance Evaluation of Black Phosphorus and Graphene Layers Using Surface Plasmon Resonance Biosensor for the Detection of CEA AntigensPhotonics · 2025
- Design and optimization of a hybrid SPR biosensor for highly sensitive detection of carcinoembryonic antigenNext Materials · 2025