Inline dissolved-gas-derived oxygen saturation reference for dynamic blood phantoms at adult-head optical properties.
E Russomanno, D Yacheur, X Yang, S Spinthaki, D Gaiki, M Ackermann, L Lanini, J Jiang,
Biomedical Optics Research Laboratory (BORL), Department of Neonatology, University Hospital Zurich, University of Zurich, Zurich, Switzerland. · D-ITET, ETH Zurich, Switzerland.
Key points
From the paper's conclusion- We conclude that IPCR provides a continuous, optically independent physicochemical reference for dynamic blood-phantom experiments.
Abstract
Dynamic liquid blood phantoms are often used to evaluate performance of near-infrared spectroscopy (NIRS) oximeters, but require a continuous and independent method to determine the "true" oxygenation (SO2), which serves as a reference. We developed IPCR (Inline PhysicoChemical Reference), which derives continuous SO2 from the inline partial pressure of oxygen (pO2), partial pressure of carbon dioxide (pCO2), pH, and temperature sensors using the hemoglobin-oxygen dissociation curve. We achieved a median propagated uncertainty of 2.1%. We tested IPCR in blood phantom experiments. IPCR agreed well with the ISS OxiplexTS (FD-NIRS) at low optical load (RMSE 3.5-4.2%, CCC > 0.99). During eight deoxygenation runs (reduced scattering coefficient between 6.0-23.0 cm-1, total hemoglobin concentration between 35-230 μM), both OxiplexTS and Masimo O3 (CW-NIRS) agreed well with IPCR at high SO2, where they provided reliable outputs. The signal quality of both NIRS devices degraded at higher optical loads, while IPCR maintained a measurement range of ∼0-100%. We conclude that IPCR provides a continuous, optically independent physicochemical reference for dynamic blood-phantom experiments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance validation of a new finger-root-adapted ring-shaped oximeter sensor during stepwise steady-state inspired hypoxia.Journal of clinical monitoring and computing · 2026
- Near-infrared spectroscopy for estimating mixed venous oxygen saturation and cardiac output during off-pump coronary artery bypass grafting: a prospective observational study.Journal of clinical monitoring and computing · 2026
- Pulse Oximetry Versus Arterial Co-Oximetry During Exercise: A Systematic Review of Agreement and Sensor Technology Reporting Gaps.Biosensors · 2026
- Real-Time SpO2 Estimation from Chest Reflectance Photoplethysmography: Algorithm Development and Clinical Validation Against Arterial SaO2.Sensors (Basel, Switzerland) · 2026
- Non-invasive near-infrared measurement of blood concentration in chest tube output: a proof-of-concept study.Biomedical physics & engineering express · 2026
- Continuous Site-Specific Intravascular Monitoring of Arterial and Venous Blood Oxygenation In Vivo.Physiological measurement · 2026