Key points
From the paper's conclusion- The 6-mm ILD strategy was inferior to the standard 4-mm strategy for acute PVI success. Despite significant gains in procedural efficiency, maintaining an ILD ≤4 mm is recommended to ensure high acute procedural success when using the TactiFlex catheter.
Abstract
BACKGROUND: Achieving pulmonary vein isolation (PVI) through contiguous lesions is important for durable PVI treatment of atrial fibrillation (AF). We hypothesized that the flexible-tip TactiFlex catheter, with its enhanced stability, would allow for successful acute PVI even with an extended interlesion distance (ILD) of 6 mm. METHODS AND RESULTS: The WILD (Wide ILD) PVI trial was a prospective, multicenter, single-blind randomized non-inferiority trial. A total of 94 patients with paroxysmal AF were enrolled and randomly allocated to either a wide ILD group (≤6 mm, n=52) or a standard ILD group (≤4 mm, n=42). The primary endpoint was acute PVI success, defined as first pass isolation without early reconnection. The non-inferiority margin was set at -10.0%. The 6-mm group did not meet the criteria for non-inferiority compared to the 4-mm group (56.7% vs. 68.7%; absolute difference: -11.9% [95% confidence interval: -25.7 to 1.8%]; P for non-inferiority=0.664). Conversely, the 6-mm strategy significantly reduced the total number of RF applications (47±10 vs. 73±17, P=0.001) and total ablation time (528±119 s vs. 825±233 s, P<0.001) compared to the 4-mm group. CONCLUSIONS: The 6-mm ILD strategy was inferior to the standard 4-mm strategy for acute PVI success. Despite significant gains in procedural efficiency, maintaining an ILD ≤4 mm is recommended to ensure high acute procedural success when using the TactiFlex catheter.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of a radiofrequency catheter ablation target based on averaged impedance drop for pulmonary vein isolationFrontiers in Cardiovascular Medicine · 2026
- Three ablation strategies using very high-power short-duration catheter in paroxysmal atrial fibrillation: The Q-INDEX randomized trial.Heart rhythm · 2026
- Procedural Efficiency and Clinical Outcomes of a Region-Specific Radiofrequency Ablation Strategy for Pulmonary Vein Isolation.Journal of arrhythmia · 2026
- Contact Index–Guided Pulsed Field Ablation: A Two‐Phase Validation of the Impedance Change Threshold to Prevent Acute Pulmonary Vein GapsJournal of Arrhythmia · 2026
- Clinical and experimental evaluation of averaged impedance drop during radiofrequency catheter ablation.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
- The Value of Inter‐Lesion Time in Linear Lesion Formation Across Varying Catheter Angles and Inter‐Lesion DistancesPacing and Clinical Electrophysiology · 2026