Procedural Efficiency and Clinical Outcomes of a Region-Specific Radiofrequency Ablation Strategy for Pulmonary Vein Isolation.
Etel Silva, Joaquín Alba-Camacho, Rafael Fernández-Rivero, Lucas Cano-Calabria, Iván Lobo-Torres, Saman Golmaryami, Ana María Solano-Mulero, Juan Fernández-Armenta
Cardiology Department, Institute of Biomedical Research and Innovation of Cádiz (INiBICA) University Hospital Puerta Del Mar Cádiz Spain.
Key points
From the paper's conclusion- A region-specific ablation strategy improved procedural efficiency without a detected difference in first-pass isolation or 12-month arrhythmia recurrence compared with ablation index-guided PVI.
Abstract
BACKGROUND: High-power short-duration radiofrequency ablation improves procedural efficiency during pulmonary vein isolation (PVI), but concerns remain regarding lesion transmurality and posterior wall collateral injury. We evaluated whether a region-specific ablation strategy was associated with improved procedural efficiency without a detected difference in acute efficacy or 12-month arrhythmia recurrence compared with conventional ablation index-guided PVI. METHODS: In this retrospective single-center study, 250 patients undergoing first-time PVI were treated with either ablation index-guided ablation or a region-specific strategy using very high-power short-duration applications on the posterior wall and ablation index-guided lesions on the anterior wall. The primary endpoint was first-pass isolation, analyzed per pulmonary vein using generalized estimating equations to account for within-patient clustering. Secondary endpoints included procedural efficiency, peri-procedural safety, and 12-month arrhythmia recurrence. RESULTS: First-pass isolation was achieved in 919 of 1 000 pulmonary veins (91.9%): 454 of 500 veins (90.8%) with the region-specific strategy and 465 of 500 veins (93.0%) with ablation index-guided ablation, with no significant between-group difference (OR, 0.74; 95% CI, 0.41-1.34; p = 0.322). The region-specific strategy was associated with shorter procedure duration, ablation time, radiofrequency time, fluoroscopy time, and lower radiation dose (all p < 0.001). Acute complications occurred in 4 patients (1.6%). At 12 months, arrhythmia recurrence occurred in 43 patients (17.2%), with no detected difference between strategies. CONCLUSIONS: A region-specific ablation strategy improved procedural efficiency without a detected difference in first-pass isolation or 12-month arrhythmia recurrence compared with ablation index-guided PVI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Unipolar electrogram-guided vs. ablation index-guided high-power short-duration pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a single-center randomized controlled trial.Quantitative imaging in medicine and surgery · 2026
- Routine single- versus double-transseptal center strategy and fluoroscopy exposure during point-by-point RF pulmonary vein isolation: insights from the Go for Zero Fluoroscopy registryEuropean Heart Journal · 2026
- Three ablation strategies using very high-power short-duration catheter in paroxysmal atrial fibrillation: The Q-INDEX randomized trial.Heart rhythm · 2026
- Clinical Impact of Interlesion Distance on Acute Pulmonary Vein Isolation Success in Patients With Paroxysmal Atrial Fibrillation.Circulation reports · 2026
- Non-complete tissue proximity indication shows perfect concordance with acute isolation gaps: an eight-segment spatial analysis during pulsed field ablation with a variable-loop circular catheterEuropean Heart Journal · 2026
- Evaluation of a radiofrequency catheter ablation target based on averaged impedance drop for pulmonary vein isolationFrontiers in Cardiovascular Medicine · 2026