The Modern Utility of Awake Deep Brain Stimulation Surgery
Bryan T. Klassen, Matthew R. Baker, Kai Joshua Miller
Mayo Clinic
Key points
From the paper's conclusion- Intraoperative physiological testing during awake Vim DBS frequently prompted trajectory adjustments that would not have been made under imaging guidance alone and were associated with improved stimulation response, underscoring the continuing role of awake testing in refining lead placement to patient-specific functional anatomy.
Abstract
BACKGROUND AND OBJECTIVES: Advances in neuroimaging and stereotactic accuracy have led many centers to adopt asleep workflows for deep brain stimulation (DBS), raising questions about the continued role of awake surgery with microelectrode recording. We evaluated whether intraoperative physiological testing during awake ventral intermediate nucleus (Vim) DBS results in trajectory adjustments that converge with the imaging-defined target. METHODS: We retrospectively reviewed 137 consecutive Vim DBS leads implanted in awake patients. For each lead, we determined whether the final implant followed the planned trajectory, required a depth adjustment, or was moved to a parallel trajectory based on microelectrode recording and test stimulation. In cases involving parallel trajectory adjustments, coregistered preoperative imaging and postoperative computed tomography were used to compare the final lead position with the imaging-defined target and determine the direction and magnitude of deviation. Intraoperative ring stimulation data were analyzed to compare tremor suppression and side effects before and after trajectory adjustment. RESULTS: Of 137 leads, 116 (85%) were implanted along the planned trajectory, including 49 at the planned depth and 67 with depth adjustments. Twenty-one leads (15%) were moved to a parallel trajectory based on intraoperative findings; 17 had data suitable for spatial analysis. Among these, 13 (76%) were moved farther from the imaging-defined target, 2 (12%) an equal distance across the target, and 2 (12%) closer. In 12 cases with paired pre- and postadjustment stimulation testing, trajectory adjustment was associated with reduced stimulation required for near tremor resolution, increased side effect thresholds, and expansion of the therapeutic window. No leads required revision. CONCLUSION: Intraoperative physiological testing during awake Vim DBS frequently prompted trajectory adjustments that would not have been made under imaging guidance alone and were associated with improved stimulation response, underscoring the continuing role of awake testing in refining lead placement to patient-specific functional anatomy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dual-target VIM-PSA deep brain stimulation using octopolar electrodes: surgical technique and feasibility study.Frontiers in neurology · 2026
- Assessing systematic spatial differences between intraoperative and postoperative Probabilistic Sweet Spots in Deep Brain Stimulation for Essential Tremor.Frontiers in human neuroscience · 2026
- Re-evaluating sources of electrode deviation in deep brain stimulation: surgical technique versus patient-specific brain mechanics.Journal of neurosurgery · 2026
- Intraoperative asymmetry of thalamic stimulation mapping in Essential Tremor: specificity of first hemisphere implantation and transitory lesioning effect.Frontiers in neurology · 2026
- Patient‐Reported Feedback Suggests an Alternative Sweet Spot for Deep Brain Stimulation Programming in Essential TremorMovement Disorders · 2026
- Can Intraoperative Therapeutic Window Data Predict Chronic Contact Selection in Deep Brain Stimulation?Current Directions in Biomedical Engineering · 2026