Assessing systematic spatial differences between intraoperative and postoperative Probabilistic Sweet Spots in Deep Brain Stimulation for Essential Tremor.
Vittoria Bucciarelli, Dorian Vogel, Jérôme Coste, Jean-Jacques Lemaire, Philippe Derost, Bérengère Debilly, Raphael Guzman, Simone Hemm
Institute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland. · Université Clermont Auvergne, Clermont Auvergne INP, CHU Clermont-Ferrand, CNRS, Institut Pascal, Clermont-Ferrand, France.
Key points
From the paper's conclusion- These findings suggest that intraoperative PSS may inform early postoperative DBS programming which could support and streamline early postoperative screening.
Abstract
INRODUCTION: Deep Brain Stimulation (DBS) is an established therapy for movement disorders such as Essential Tremor (ET). While electrode displacement across intraoperative and postoperative stages has been studied, Probabilistic Sweet Spot (PSS) analyses rarely account for temporal evolution. Consequently, it remains unclear whether intraoperatively identified optimal stimulation sites are spatially stable over time and can reliably inform postoperative programming. This study investigated systematic differences between intraoperative and postoperative PSS locations, both at cohort and individual patient levels. METHODS: Intraoperative (N = 324) and postoperative (N = 566) stimulation tests were retrospectively analyzed from 14 ET patients. Electric field simulations were performed for all tested stimulation settings. Voxel-wise statistical testing was applied to compute intraoperative and postoperative PSSs at both the group and patient-specific levels. PSSs volumes and centroid locations were compared between time points using spatial overlap metrics and displacement analyses. RESULTS: A partial spatial concordance between intraoperative and postoperative PSSs at different symptom improvement thresholds was observed at the group level, with a maximum Dice coefficient of 0.75. Overlap decreased between regions associated with higher tremor suppression. At the individual level, a consistent anterior-posterior displacement was identified in the left hemisphere, with intraoperative PSSs located more posteriorly than postoperative PSSs (mean displacement ≈1.5 mm). DISCUSSION: Modest but systematic spatial differences exist between intraoperative and postoperative PSS; however, their magnitude remains within a few millimeters, and a considerable spatial overlap is observed. These findings suggest that intraoperative PSS may inform early postoperative DBS programming which could support and streamline early postoperative screening.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intraoperative asymmetry of thalamic stimulation mapping in Essential Tremor: specificity of first hemisphere implantation and transitory lesioning effect.Frontiers in neurology · 2026
- Patient‐Reported Feedback Suggests an Alternative Sweet Spot for Deep Brain Stimulation Programming in Essential TremorMovement Disorders · 2026
- Inhibitory Evoked Potentials as a Spatially Dependent Intraoperative Marker of Clinical Tremor ReductionbioRxiv · 2026
- Pseudo-monopolar sensing of subthalamic beta power helps to predict optimal DBS contacts in Parkinson's DiseasemedRxiv · 2026
- Can Intraoperative Therapeutic Window Data Predict Chronic Contact Selection in Deep Brain Stimulation?Current Directions in Biomedical Engineering · 2026
- Three-Dimensional Point-Cloud Learning for Patient-Specific Deep Brain Stimulation Motor Response Prediction in Parkinson Disease.BME frontiers · 2026