From the paper's conclusion
  • The intraoperative CT registration workflow, compared with laser facial scanning, provided significantly lower stereotactic error across all 3 error metrics. Laser facial scanning still offered an adequate error profile for SEEG. Depending on clinical necessity, these results validate intraoperative CT registration as an important step in accurate robotic-guided SEEG.

Abstract

BACKGROUND AND OBJECTIVES: Stereoelectroencephalography (SEEG) is an important methodology for invasive evaluation in medically refractory epilepsy patients. Traditionally, laser-based facial scanning has been used for stereotactic robotic registration at our center. More recently, we developed and validated a noninvasive, frame-based fiducial system integrated with intraoperative computed tomography (CT) registration, as part of our SEEG workflow. This study aims to compare the stereotactic accuracy in SEEG electrode placement using these 2 approaches. METHODS: Registration error, implantation accuracy metrics, and perioperative variables were collected for 56 refractory epilepsy patients undergoing SEEG between April 2022 and March 2024. Thirty-four patients underwent intraoperative CT registration, and 22 patients underwent laser facial scanning registration. Entry-point error, target-point error, and angular error metrics were measured for every electrode trajectory, across 1059 electrodes total. Wilcoxon rank sum tests were used to compare error measures between registration modalities. RESULTS: Overall mean age was 27.7 ± 11.2 years, with a mean of 28.3 ± 10.2 years in the laser group and 27.3 ± 12.0 years in the CT group. The average number of electrodes implanted was 19 ± 3 (intraoperative CT: 20 ± 3; laser: 19 ± 3). The average entry-point error was 1.52 ± 0.91 mm (intraoperative CT: 1.28 ± 0.83 mm; laser: 1.87 ± 0.90 mm; P < .0001). The average target-point error was 2.75 ± 1.48 mm (intraoperative CT: 2.65 ± 1.43 mm; laser: 2.89 ± 1.53 mm; P = .0050). The average angular error was 0.051 ± 0.038 radians (intraoperative CT: 0.045 ± 0.032 radians; laser: 0.060 ± 0.045 radians; P < .0001). CONCLUSION: The intraoperative CT registration workflow, compared with laser facial scanning, provided significantly lower stereotactic error across all 3 error metrics. Laser facial scanning still offered an adequate error profile for SEEG. Depending on clinical necessity, these results validate intraoperative CT registration as an important step in accurate robotic-guided SEEG.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Trajectory Metric Analysis in Stereotactic Robotic-Guided Stereoelectroencephalography: Fiducial-Based Intraoperative Computed Tomography Versus Laser Facial Scanning Registration Workflows — Science Skim