SEEG Contact Detector: A 3D Slicer Extension for Automated Localisation of Intracranial Electrode Contacts
J. Smid, P. Jezdik, A. Kalina, M. Kudr, R. Janca
Key points
From the paper's conclusion- This study presents an open-source extension for 3D Slicer that provides an integrated, user-friendly standalone solution for the direct automatic detection of electrode contacts within a widely used medical imaging platform.
Abstract
Background: Precise localisation of intracranial electrode contacts is essential for the interpretation of stereoelectroencephalography recordings and planning epilepsy surgery. In current clinical practice, this is typically a manual process, which is time-consuming and prone to variability. Existing automated solutions are often fragmented across multiple tools requiring technical expertise, limiting their adoption in routine clinical workflows. This study presents an open-source extension for 3D Slicer that provides an integrated, user-friendly standalone solution for the direct automatic detection of electrode contacts within a widely used medical imaging platform. Results: The proposed method combines anchor bolt-based initialisation, probabilistic segmentation of electrode structures, and non-linear modelling to precisely track true electrode trajectories. The approach was evaluated on a dataset comprising 78 cases from 73 patients, including 1,078 electrodes with 14,480 contacts. The method achieved high localisation accuracy, with a median (interquartile range) deviation of 0.10 (0.06, 0.15) mm. Only 7/1078 (0.65%) electrodes required manual correction; these specific cases were handled using tools provided within the proposed extension. Conclusions: The presented extension enables fast, accurate, and reproducible electrode contact localisation within a single integrated environment. By combining automation with intuitive user interaction, it significantly reduces processing time while maintaining clinical reliability. The tool's free availability as an extension in 3D Slicer lowers the barrier to adoption and supports the standardisation of workflows across clinical and research centres.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Robotic Arm Alignment System for Electrode Implantation in Invasive Epilepsy Monitoring: Clinical Experience and Accuracy in a Consecutive Patient Series with Comparison to the Literature.Journal of clinical medicine · 2026
- sEEG-Suite: An Interactive Pipeline for Semi-Automated Contact Localization and Anatomical Labeling with BrainstormThe Journal of Open Source Software · 2026
- Omni-iEEG Planner: an open-source Python platform integrating multimodal neuroimaging and intracranial EEG data for epilepsy surgery researcharXiv · 2026
- How well does electrical source imaging reconstruct neural time series? Evidence from simultaneous scalp and intracranial EEG recordingsbioRxiv · 2026
- Trajectory Metric Analysis in Stereotactic Robotic-Guided Stereoelectroencephalography: Fiducial-Based Intraoperative Computed Tomography Versus Laser Facial Scanning Registration Workflows.Operative neurosurgery (Hagerstown, Md.) · 2026
- Patient-independent seizure onset zone localization with generalizable feature learning and multi-task supervision.Neural networks : the official journal of the International Neural Network Society · 2026