Ultra-Rapid β2-Transferrin Lateral Flow Immunoassay Enables Accurate Point-of-Care Detection of Cerebrospinal Fluid.
Morteza Sadeh, Abdulrhman Alsalama, Tatiana Abou-Mrad, Sergey Neckrysh
Department of Neurosurgery, University of Illinois Chicago, Chicago, Illinois, USA.
Key points
From the paper's conclusion- This feasibility study supports the potential utility of a rapid β2-transferrin LFA as a simple point-of-care assay for CSF detection. Larger prospective validation in real-world rhinorrhea, otorrhea, wound-drainage, and postoperative leak samples is warranted.
Abstract
BACKGROUND AND OBJECTIVES: Cerebrospinal fluid (CSF) leak diagnosis often relies on laboratory β2-transferrin testing, which is specific but not optimized for immediate bedside decision making. We air to evaluate a rapid β2-transferrin lateral flow immunoassay (LFIA) for point-of-care CSF detection. METHODS: Human CSF samples were obtained from adult patients with external ventricular drains and tested using a blinded, standardized LFA protocol. Sterile saline and non-CSF drain fluid served as negative controls. Selected CSF samples underwent 1:10 and 1:100 saline dilution. Results were classified as positive, negative, or invalid/inconclusive and summarized descriptively. RESULTS: A total of 399 assay runs were included. Raw CSF was positive in 232 of 232 tests. CSF:saline 1:10 samples were positive in 23 of 25 tests, with 2 invalid/inconclusive results, and CSF:saline 1:100 samples were positive in 20 of 20 tests. Saline controls showed 0 positive results in 98 tests. Drain-fluid controls showed 0 positive results in 24 tests, with 23 negative and 1 invalid/inconclusive result. Among cassette-positive samples with valid timing, the median time to positivity was 14.0 minutes for raw CSF, 5.0 minutes for 1:10 CSF:saline, and 8.6 minutes for 1:100 CSF:saline. CONCLUSION: This feasibility study supports the potential utility of a rapid β2-transferrin LFA as a simple point-of-care assay for CSF detection. Larger prospective validation in real-world rhinorrhea, otorrhea, wound-drainage, and postoperative leak samples is warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-162 Cut-off value for ß-trace protein (ß-TP) as a rapid diagnostic of cerebrospinal fluid (CSF) leak detectionClinical Chemistry · 2026
- Bedside Feasibility and Preliminary Diagnostic Performance of the Point-of-Care Combined Lactate-Glucose Ratio for Detecting Cerebrospinal Fluid Infection in Neurosurgical Patients: A Pilot Study.Korean journal of neurotrauma · 2026
- β-TP For Diagnosing CSF Leak After the Endoscopic Endonasal Approach Surgery for Sellar Tumors.The Laryngoscope · 2026
- Diagnostic accuracy of urine test strips for CSF analysis: high sensitivity in detecting blood, low sensitivity but high specificity in detecting inflammation.Frontiers in neurology · 2026
- Microfluidic platform for rapid passive preparation of complex biological matrices in point-of-care testing.Scientific reports · 2026
- A Lateral Flow-Based Whole Blood Sample Preparation for Surface Plasmon Resonance Sensing of Ferritin in Frequent Blood Donors.ACS sensors · 2026