A Lateral Flow-Based Whole Blood Sample Preparation for Surface Plasmon Resonance Sensing of Ferritin in Frequent Blood Donors.
Caroline Dubois, Noémie Loranger, Jonathan Robidoux, David Geilfus, Jason Malefant, Danny Brouard, Jean-François Masson
Département de chimie, Institut Courtois, Quebec Center for Advanced Materials, Regroupement Québécois sur les Matériaux de Pointe, and Centre interdisciplinaire de Recherche sur le Cerveau et l'Apprentissage, Université de Montréal, 1375 ave. Thérèse-Lavoie-Roux, Montréal, QuebecH2V 0B3, Canada. · Héma-Québec, Affaires médicales et innovation , 1070, avenue des Sciences-de-la-Vie, Québec City, QuébecG1V 5C3, Canada.
Key points
From the paper's conclusion- To address this need, we developed a portable POC surface plasmon resonance (SPR) assay for rapid ferritin quantification from whole blood that uses a lateral flow-based sample preparation strip to collect an eluate from whole blood.
Abstract
Measurements from whole blood remain challenging with plasmonic techniques, especially for point-of-care (POC) measurements where infrastructure is limited. To address this need, we developed a portable POC surface plasmon resonance (SPR) assay for rapid ferritin quantification from whole blood that uses a lateral flow-based sample preparation strip to collect an eluate from whole blood. The concept is shown with clinical samples for monitoring iron deficiency anemia (IDA), a prevalent global health concern considered with care by blood banks, for which rapid POC quantification has yet to be achieved. The SPR assay detected ferritin concentrations in the ng/mL range from whole blood in 30 min, sufficient to discriminate concentrations at the clinically relevant threshold for IDA. Measurements from eluted blood showed good agreement with centrifuged serum and enzyme-linked immunosorbent assay (ELISA) results, allowing clear classification between deficient and normal ferritin levels despite minor variability among clinical samples collected from blood donors. With its portability, short analysis time, and minimal sample preparation, this method demonstrates strong potential for on-site protein sensing, as exemplified for ferritin screening at blood drives with minimal and simple blood preparation, providing a pathway toward future development of point-of-care tools for improved assessment of donor iron status.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Field-Oriented Application of Commercial Lateral Flow Immunoassay for African Swine Fever Virus Using On-Site Tissue Homogenization.Pathogens (Basel, Switzerland) · 2026
- Multimodal LFIA platform integrating visual readout, smartphone grayscale imaging and surface-enhanced Raman scattering for point-of-care detection of SARS-CoV-2 protein.Analytical methods : advancing methods and applications · 2026
- Magnetization Dynamics-Modulated Near-Infrared Mie Scattering Enables Homogeneous Femtomolar Immunosensing for Whole Blood.ACS nano · 2026
- Fe3O4-Au cluster-satellite particles as direct colorimetric reporters in a smartphone-quantified lateral flow immunoassay for prostate-specific antigen.Mikrochimica acta · 2026
- Nanomaterial-Enabled Fiber-Optic SPR Biosensor for Continuous and Noninvasive Body Fluid Monitoring:Progress and Prospects.Nanomaterials (Basel, Switzerland) · 2026
- Microfluidic platform for rapid passive preparation of complex biological matrices in point-of-care testing.Scientific reports · 2026