Comparison of visual estimation of ventricular systolic function with quantitative echocardiographic markers in newborn infants
Sujith S. Pereira, Beena Yeldo, Rachael Fleming, Saulius Šatas
Queen Mary University of London · Homerton University Hospital
Key points
From the paper's conclusion- We compared visual estimation with standard quantitative echocardiographic markers such as shortening fraction, Simpson’s ejection fraction and global longitudinal strain for left ventricle and tricuspid annular plane systolic excursion and fractional area change for right ventricle.
Abstract
BACKGROUND: Neonatologist-performed echocardiography (NPE) is increasingly practiced. NPE operators typically use visual estimation of systolic function and, if indicated, confirm function using quantitative echocardiographic markers. This exploratory study aims to compare the concordance between qualitative and quantitative echocardiographic markers among NPE and non-NPE operators. METHODS: We studied a cohort of newborn infants, undergoing routine NPE by the authors at Homerton University Hospital and Aberdeen Maternity Hospital from April 2024 to October 2024. Blinded NPE and non-NPE operators independently assessed left and right ventricular systolic function visually. We compared visual estimation with standard quantitative echocardiographic markers such as shortening fraction, Simpson's ejection fraction and global longitudinal strain for left ventricle and tricuspid annular plane systolic excursion and fractional area change for right ventricle. We examined the concordance between visual estimation and quantitative echocardiographic markers for biventricular systolic function. RESULTS: Sixty infants with a mean (SD) gestation and birth weight of 34 (6.2) weeks and 2311 (1319) grams respectively were examined. Sensitivity testing for all echocardiographic parameters ranged from 25% to 80% whereas specificity ranged from 38% to 78%. Sensitivity increased with worsening grades of LV dysfunction defined using shortening fraction. While concordance between NPE and non-NPE operator was generally limited across most echocardiographic parameters, test-retest reliability was acceptable for several quantitative measures, including Simpson's ejection fraction, global longitudinal strain and right ventricular fractional area change. CONCLUSION: Visual estimation may be a useful bedside tool for detecting severe ventricular dysfunction in newborn infants; however; quantitative echocardiographic measures are likely to improve the assessment of mild to moderate dysfunction. Further studies should confirm these findings in a larger cohort with a higher representation of infants with ventricular dysfunction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Beyond the Image: Pitfalls, Cognitive Biases, and Safety Gaps in Non-Cardiac Neonatal Point-of-Care Ultrasound.Children (Basel, Switzerland) · 2026
- Comparative Diagnostic Accuracy of Point-of-Care Ultrasound for Detecting Reduced Left Ventricular Systolic Function: A Systematic Review and Meta-Analysis.Journal of general internal medicine · 2026
- Quantitative Ultrasound Imaging and Artificial Intelligence in Neonatal Echocardiography: Methodological Advances, Reproducibility Challenges, and Computational Perspectives.Journal of imaging · 2026
- Digital profile of children’s hearts: automated echocardiogram strain analysis facilitates earlier detection of cardiac dysfunctionEuropean Heart Journal · 2025
- AI-assisted echocardiographic assessment of left ventricular function in primary care: a prospective implementation studyEuropean Heart Journal · 2026
- Decision Limits for Fetal Speckle-Tracking Outputs: Minimal Detectable Change and Threshold Instability in FetalHQ.Biomedicines · 2026