Beyond the Image: Pitfalls, Cognitive Biases, and Safety Gaps in Non-Cardiac Neonatal Point-of-Care Ultrasound.
Adrian Costache, Diana Iulia Vasilescu, Sorin Liviu Vasilescu, Andreea Raluca Gogoncea, Adriana Mihaela Dan
Faculty of Medicine, "Carol Davila" University of Medicine and Pharmacy, 020956 Bucharest, Romania. · Department of Neonatology, "Grigore Alexandrescu" Clinical Emergency Children Hospital Bucharest, 011743 Bucharest, Romania.
Key points
From the paper's conclusion- We also separate errors that can occur in any ultrasound examination from those tied to the point-of-care setting, including confirmation, anchoring, and availability bias, time pressure, and fatigue.
Abstract
Point-of-care ultrasound (POCUS) is now part of everyday work in neonatal intensive care, supporting diagnosis, procedures, and decisions in acutely unwell infants. Its spread has outpaced the development of training, credentialing, and quality assurance structures, and the neonatal literature rarely describes how and why the technique fails. In this perspective, we focus on non-cardiac neonatal POCUS (lung, cranial, and abdominal). We adapt existing frameworks into four error domains: indication, image acquisition, image interpretation, and clinical integration. We also separate errors that can occur in any ultrasound examination from those tied to the point-of-care setting, including confirmation, anchoring, and availability bias, time pressure, and fatigue. Using illustrative cases and comparative tables, we describe common look-alike findings, summarize thermal and mechanical bioeffects by organ, and discuss probe and gel hygiene in the neonatal unit. We then outline a stepwise pathway for training, supervision, credentialing, and quality assurance, and suggest practical safeguards: structured protocols and reports, simple debiasing habits, image archiving with periodic expert review, and close collaboration with radiology and cardiology. Seen in this way, investment in safety is part of the value of neonatal POCUS rather than an added cost.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Comprehensive Review of the Approach to Ultrasonography in Neonatal Shock: The Partnership Between Targeted Neonatal Echocardiography and Point-of-Care Ultrasound.Children (Basel, Switzerland) · 2026
- Evolution of POCUS in the NICU: From a diagnostic tool to an extension of clinical examination.Seminars in fetal & neonatal medicine · 2026
- The Application of Nurse‐Led Bedside Critical Care Ultrasound in Paediatric and Neonatal Nursing Practice: A Scoping ReviewNursing in Critical Care · 2026
- Point-of-care ultrasound in neonatal necrotizing enterocolitis: integrating clinician-performed evidence and nurse-led implementation.Frontiers in pediatrics · 2026
- Perioperative POCUS: Technical Considerations and Applications for the Pediatric Anesthesiologist.Journal of clinical medicine · 2026
- Clinical Imaging: Point-of-care Ultrasound for Endotracheal Tube Localization in Neonates: Why It MattersNewborn · 2026