Dual-threshold graded desaturation protection for IGBTs in VSC-HVDC converter valve submodules
Wenqian Yuan, Yirun Ji, Yu Li, Qing Huai, Xi Yuan, Ziyao Jie, Linzi Zheng, Bin Huang,
Key points
From the paper's conclusion- The results show that the optimized high-threshold protection reduces the protection operating time by approximately 47% compared with the conventional scheme, while the low-threshold protection effectively clears faults during slowly rising overcurrent conditions.
Abstract
A dual-threshold graded desaturation protection strategy is proposed to address differences in the short-circuit current evolution and protection requirements of insulated-gate bipolar transistors (IGBTs) under different short-circuit conditions in converter valve submodules for voltage-source-converter-based high-voltage direct-current (VSC-HVDC) transmission. The high-threshold channel uses independently configured detection-circuit parameters and a shortened blanking time to provide fast protection under low-inductance short-circuit conditions. The low-threshold channel uses a trip level determined from the device output characteristics and requires the detection voltage to remain above this level for a specified duration to identify slowly rising overcurrents under high-inductance short-circuit conditions. A first-order dynamic model of the detection voltage is established to derive coordination constraints among the detection threshold, response time constant, and confirmation delay. Experiments are conducted for three protection configurations: conventional high-threshold protection, optimized high-threshold protection, and low-threshold protection. The results show that the optimized high-threshold protection reduces the protection operating time by approximately 47% compared with the conventional scheme, while the low-threshold protection effectively clears faults during slowly rising overcurrent conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- System-Level Optimization of Hybrid Diode–Thyristor Fault Current Limiters for Multi-Terminal HVDC ProtectionEnergies · 2026
- Coordinated Fault Ride-Through Control for a Hierarchically Connected VSC-HVDC SystemEnergies · 2026
- Voltage Support Strategy for a Hybrid-Infeed HVDC System with VSC-HVDC and LCC-HVDCApplied Sciences · 2026
- A Virtual Resistance-Capacitance Control Strategy for Mitigating Consecutive Commutation Failures in Weak Receiving-End HVDC SystemsEnergies · 2026
- Adaptive DC-Line Reclosing Strategy for VSC-HVDC Transmission from Desert–Gobi–Wasteland Renewable Energy BasesEnergies · 2026
- Voltage-Disturbance Identification and Fast Transfer Control of an IGCT-Based Hybrid Solid-State Transfer Switch.Sensors (Basel, Switzerland) · 2026