Neurological research and practice

Heparin-calibrated anti-factor Xa activity as a surrogate marker for direct oral anticoagulant levels in acute stroke care: a large observational single-center study.

Martin Büchsel, Katharina Lisko, Hanna Gölz, Jürgen Bardutzky, Heinz Wiendl, Saúl Beltrán Felipa, Johann Lambeck

Institute for Clinical Chemistry and Laboratory Medicine, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany. martin.buechsel@uniklinik-freiburg.de. · Department of Neurology and Clinical Neurophysiology, University of Freiburg Medical Center, Breisacherstr. 64, 79106, Freiburg, Germany.

Observational · n=969

Key points

From the paper's conclusion
  • Heparin-calibrated anti-Xa activity is a reliable surrogate marker for clinically relevant DOAC levels. Defined anti-Xa cut-offs are highly specific and sensitive and enable rapid and standardized assessment of anticoagulant activity in this cohort.

Abstract

BACKGROUND AND PURPOSE: Direct oral anticoagulants (DOAC) complicate therapeutic decision-making, as rapid assessment of anticoagulant activity is critical in emergency patients, particularly in acute ischemic stroke (AIS). The administration of systemic thrombolysis (IVT) in anti-coagulated patients requires careful risk-benefit evaluation, given the potential for hemorrhagic complications. Substance-specific DOAC plasma level measurements are often unavailable outside tertiary centers. This study evaluated whether widely available heparin-calibrated anti-factor Xa (anti-Xa) activity can reliably estimate clinically relevant DOAC levels and support urgent clinical decision-making. METHODS: This retrospective single-center study (2015-2023) analyzed 969 patients treated with apixaban, rivaroxaban, or edoxaban. All patients had parallel measurements of anti-Xa activity and specific DOAC levels. Correlations were assessed using Spearman's coefficient. Receiver operating characteristic (ROC) analyses were performed to derive anti-Xa cut-off values corresponding to DOAC concentrations of 30, 50, and 100 ng/mL. RESULTS: Anti-Xa activity strongly correlated with DOAC plasma levels for all substances (Spearman's ρ ≈ 0.95-0.96). ROC analyses demonstrated excellent diagnostic accuracy, with areas under the curve ≥ 0.97 for all evaluated thresholds. Similar anti-Xa cut-offs were observed for apixaban and rivaroxaban, whereas these were lower for edoxaban. For all DOACs combined, anti-Xa cut-offs of approximately 0.36U/mL, 0.56U/mL, and 1.19U/mL corresponded to DOAC levels of 30, 50, and 100ng/mL, respectively, with high sensitivity and specificity. CONCLUSIONS: Heparin-calibrated anti-Xa activity is a reliable surrogate marker for clinically relevant DOAC levels. Defined anti-Xa cut-offs are highly specific and sensitive and enable rapid and standardized assessment of anticoagulant activity in this cohort.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.