Real-World Assessment of Direct Oral Factor Xa Inhibitors: Dosing Appropriateness, Drug Exposure, and Inter-Platform Comparability of Chromogenic Anti-Xa Assays.
Yoonjung Kim, Sojin Lee, Yongjung Park, Kyung-A Lee
Department of Laboratory Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 06273, Republic of Korea. · Department of Laboratory Medicine, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin 16995, Republic of Korea.
Key points
From the paper's conclusion- Despite receiving a class 2a recommendation in recent American College of Cardiology guidelines for atrial fibrillation prevention, PP is not widely performed. Given its simplicity, safety, and effectiveness, wider use of PP could improve outcomes after cardiac surgery.
Abstract
Background/Objectives: Direct oral factor Xa inhibitors (DOACs) show substantial interindividual exposure variability in real-world practice, yet interpretation of plasma drug concentrations remains challenging because routine monitoring is not standardized. This study evaluated dosing appropriateness, plasma drug exposure measured by chromogenic anti-factor Xa assays, inter-platform comparability, and associations with routine coagulation tests. Methods: This single-center retrospective study included 392 plasma samples from 292 patients with atrial fibrillation treated with apixaban (n = 207), edoxaban (n = 147), or rivaroxaban (n = 38). Post-dose outpatient spot samples were analyzed using Sysmex CS-5100 and CN-6000 analyzers with two chromogenic anti-factor Xa assay systems (BIOPHEN™ DiXaI and BIOPHEN™ Heparin LRT) and drug-specific calibrators. Correlations between routine assays (prothrombin time [PT]/international normalized ratio [INR], activated partial thromboplastin time [aPTT]) and DOAC concentrations, as well as inter-platform agreement, were assessed using Spearman's rank correlation and Passing-Bablok regression. Dosing appropriateness was determined according to Food and Drug Administration-approved labeling. Results: Overall dosing appropriateness was 69.2% (edoxaban 73.3%, apixaban 70.5%, rivaroxaban 45.5%), whereas inappropriate underdosing was the predominant prescribing pattern (26.9%), particularly among patients without formal dose-reduction criteria. PT/INR demonstrated the strongest correlation with edoxaban concentrations (rs = 0.83, p < 0.001). Inter-analyzer correlation between the CS-5100 and CN-6000 was excellent (r = 0.885-0.996), with LRT reagents providing highly consistent results across platforms. Conclusions: Real-world outpatient DOAC concentrations demonstrated substantial variability and frequent off-label underdosing. Chromogenic anti-factor Xa assays showed strong inter-platform agreement, particularly with LRT reagents, supporting their analytical reliability for laboratory assessment of DOAC exposure. Because exact dosing times were unavailable, these concentrations should be interpreted as heterogeneous spot samples rather than standardized pharmacokinetic reference intervals; these findings may nonetheless support individualized interpretation of outpatient spot sample DOAC concentrations in selected clinical settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessment of Direct Oral Anticoagulant Plasma Concentrations Before Elective Electrical Cardioversion.Medicina (Kaunas, Lithuania) · 2026
- Adherence to Direct Oral Anticoagulants in Patients With Non-valvular Atrial Fibrillation: A Single-Center Retrospective Study.Journal of cardiovascular pharmacology and therapeutics · 2026
- Oral Anticoagulation Registry in Patients with Atrial Fibrillation Treated in Primary Care in Clinical Practice: The RACOVIR Study.Journal of clinical medicine · 2026
- Clinical decision support tool evaluation: Correction of direct oral anticoagulant dosing errors by clinical pharmacists and physicians.Research and practice in thrombosis and haemostasis · 2026
- Long-term analytical performance of apixaban measurements based on external quality assessment data.Thrombosis research · 2026
- Heparin-calibrated anti-factor Xa activity as a surrogate marker for direct oral anticoagulant levels in acute stroke care: a large observational single-center study.Neurological research and practice · 2026