Feasibility of real-time 1.5-T MR-guided percutaneous irreversible electroporation in a porcine model.
Othmar Belker, Simon Schröer, Thomas Gerlach, Max Joris Hubmann, Daniel Düx, Marcel Eisenmann, Christoph Fritsch, Julian Glandorf,
Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany. belker.othmar@mh-hannover.de. · Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
Key points
From the paper's conclusion- These findings demonstrate the procedural feasibility of MR-guided percutaneous IRE in clinical 1.5-T MR systems.
Abstract
This exploratory study assessed the procedural feasibility of in‑bore, real‑time magnetic resonance (MR)‑guided percutaneous irreversible electroporation (IRE) using a clinical 1.5-T system in a porcine model. Three healthy anesthetized juvenile swine underwent IRE in normal renal tissue using a prototype pulse generator and MR-conditional coaxial cannula as electrodes. One swine was ablated twice in the same kidney, resulting in statistically non-independent data. The procedure was guided by a balanced steady-state free precession sequence with orthogonal slices and intermittent position verifications using a radial three-dimensional gradient-echo sequence. Preprocedure radiofrequency noise and signal-to-noise ratio measurements showed slightly increased noise levels in generator standby mode without apparent imaging artifacts. Median procedure time was 48 min with an interquartile range of 17 min. Four hours post-procedure, the treatment zone appeared T1-hypointense in delayed contrast-enhanced imaging. For one treatment zone, hematoxylin and eosin staining (H&E), fluorescent terminal deoxynucleotidyl transferase-mediated dUTP nick-end labeling staining (TUNEL), and coregistration to MR imaging were performed. H&E showed minor hemorrhaging at the site of electrode insertion. TUNEL demonstrated a strong TUNEL-positive signal correlating with the T1-hypointense signal in delayed contrast-enhanced imaging, with a Dice-Sørensen coefficient of 67%. These findings demonstrate the procedural feasibility of MR-guided percutaneous IRE in clinical 1.5-T MR systems. KEY POINTS: Question Can MR-guided percutaneous irreversible electroporation be performed in a porcine model despite the lack of MR-compliant devices? Findings In four irreversible electroporation procedures in three juvenile pigs, electrodes were successfully placed in the kidney using real-time guidance in a clinical 1.5-T scanner. Relevance statement Real-time MR-guided percutaneous irreversible electroporation is procedurally feasible in a clinical 1.5-T MRI environment, while preserving image quality and enabling arbitrary slice positioning. Further research is required to confirm the reproducibility and enable the translation to oncological applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Robot-assisted Partial Nephrectomy with and without Mixed Reality - REALITATEM studyInternational braz j urol · 2026
- Multistage preclinical evaluation of a retrievable 3 T MR-resonant inferior vena cava filter and snare loop for MRI-guided interventions.CVIR endovascular · 2026
- Multistage Preclinical Evaluation of MRI-Guided Stenting for Coarctation of the Aorta using in vitro and Porcine Models.Cardiovascular and interventional radiology · 2026
- Multiparametric MRI for In Vivo Visualization of Renal Inflammation in Acute Kidney Injury.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Safety and Efficacy of an Irreversible Electroporation System with Real-Time Electrical and Thermal Monitoring for Liver Tumors: A Bicentric Retrospective Study.Cardiovascular and interventional radiology · 2026
- Establishment and Optimization of a Mouse Model of Myocardial Ischemia-Reperfusion Injury.Journal of visualized experiments : JoVE · 2026