Optimization of PET acquisition time for thoracic lesions in 18F-FDG PET/MRI: a retrospective analysis.
Haifeng Gu, Yue Jiang, Jun Cai, Gang Yang, Jianrui Li, Sui Chen, Song Luo, Longjiang Zhang
Department of Diagnostic Radiology, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China. · Department of Diagnostic Radiology, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China. hnldls@163.com.
Key points
From the paper's conclusion- Key Points Question What is the minimum PET acquisition time for chest 18F-FDG PET/MRI that maintains image quality and lesion detectability equivalent to a 20‑min reference?
Abstract
OBJECTIVE: This study aimed to define the minimum positron emission tomography (PET) acquisition time for chest PET/magnetic resonance imaging (MRI), providing image quality and lesion detectability comparable to a 20-min reference. MATERIALS AND METHODS: In this retrospective study, list-mode data from 101 patients undergoing chest 18F-fluorodeoxyglucose (18F-FDG) PET/MRI on a 3-T PET/MRI system were reconstructed to simulate 10 acquisition times (0.5-20 min). Two readers assessed subjective image quality using a 5-point Likert scale. Quantitative parameters, including maximum, mean of the lesion standardized uptake value (L_SUVmax, L_SUVmean), image noise ratio (INR), and lesion-to-background ratio (LBR), were measured. Lesion detectability was defined as the miss rate relative to lesions visible on the 20-min reference acquisition. RESULTS: In 101 patients, 283 lesions were identified. Subjective scores increased from a median of 2 (interquartile range 2-2) at 0.5 min to 5 (5-5) at 7 min (p < 0.001), then plateaued (7-20 min; all p = 1.000). L_SUVmax, L_SUVmean, and LBR inversely correlated with scan duration (all p < 0.001). L_SUVmean stabilized at 3 min (p = 1.000), while L_SUVmax/LBR stabilized at 5 min (p = 1.000). INR required 10 min (p ≥ 0.054). Lesion miss rates increased time dependently, from 0% at 15 min to 7.77% at 0.5 min. CONCLUSION: A 7-min acquisition time provided subjective quality and detectability comparable to the 20-min protocol, supporting routine use. For quantitative assessments, 3-5 min sufficed, and patients with shorter 18F-FDG uptake or larger lesions may be adequately assessed with 2 min. KEY POINTS: Question What is the minimum PET acquisition time for chest 18F-FDG PET/MRI that maintains image quality and lesion detectability equivalent to a 20‑min reference? Findings A 7‑min PET acquisition matches 20‑min image quality and detectability; quantitative parameters stabilize at 3‑5 min; 2 min suffices for patients with shorter uptake or larger lesions. Relevance statement Reducing PET acquisition time to 7 min enhances patient comfort, reduces motion artifacts, and increases scanner throughput without compromising chest PET/MRI diagnostic performance, thereby improving patient experience and workflow efficiency. Further clinical validation is needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Modelling image quality over extended [18F]FDG uptake times for low-dose positron emission mammography.Frontiers in oncology · 2026
- Deep progressive reconstruction for low-dose ¹⁸F-FDG PET/CT imaging in pediatric patients.Annals of nuclear medicine · 2026
- Test-Retest Repeatability of [18F]FDG Uptake by Solid Tumors on PET/MRI: A Prospective, Multicenter Study Using the QIBA Protocol.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
- A rapid total-body PET imaging approach for pediatric patients using non-attenuation-corrected PET scansEJNMMI Physics · 2026
- Treatment response evaluation in extraspinal musculoskeletal tuberculosis using molecular imaging (18F-fluorodeoxyglucose PET/computed tomography): a prospective observational study.Nuclear medicine communications · 2026
- A two-stage PET/MRI attenuation-correction workflow for pseudo-CT and AC PET synthesis with GUI-based inference.Medical & biological engineering & computing · 2026