A two-stage PET/MRI attenuation-correction workflow for pseudo-CT and AC PET synthesis with GUI-based inference.
Seyede Sajede Mousavi Eshkiki, Alireza Sadremomtaz
Department of Physics, University of Guilan, Rasht, Iran. · Department of Physics, University of Guilan, Rasht, Iran. sadremomtaz@yahoo.co.uk.
Key points
From the paper's conclusion- These findings support internal CERMEP feasibility, while nested and external validation remain necessary.
Abstract
Quantitative positron emission tomography/magnetic resonance imaging (PET/MRI) requires reliable attenuation correction, but MRI does not directly encode attenuation-related tissue information. This study implemented and internally evaluated a graphical user interface (GUI)-supported two-stage brain PET/MRI workflow for pseudo-computed tomography (pseudo-CT) generation and PET attenuation-correction synthesis using the CERMEP-IDB-MRXFDG cohort. The objective was not to introduce a new neural-network architecture, but to evaluate an attenuation-informed workflow that sequentially combines MRI-based pseudo-CT generation, attenuation-map estimation, and NAC PET correction. Thirty-seven normal adult subjects were analyzed using subject-level five-fold cross-validation. A first-stage two-dimensional U-Net predicted pseudo-CT from T1-weighted MRI. The pseudo-CT output was converted into an approximate 511-keV linear attenuation coefficient map (μ-map) and combined with non-attenuation-corrected (NAC) PET as input to a second U-Net for predicted attenuation-corrected (AC) PET synthesis. Patient-level pseudo-CT errors, image-similarity metrics, Bland-Altman agreement, and exploratory standardized uptake value (SUV) metrics were evaluated. The pseudo-CT model achieved whole-image mean absolute error (MAE) of 72.26 ± 20.11 HU and structural similarity index measure (SSIM) of 0.881 ± 0.024, with bone-dominated residual error. Predicted AC PET achieved 76.02% lower normalized MAE and 73.33% lower normalized root mean square error (RMSE) than NAC PET relative to reference AC PET. Exploratory SUV analysis showed mean percentage errors of 8.66% for SUVmean and 22.08% for SUVmax, with greater inter-subject variability in SUVmax. These findings support internal CERMEP feasibility, while nested and external validation remain necessary.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Open-access template and database approaches for pseudo-CT generation in brain PET/MRI attenuation correction.NeuroImage · 2026
- PET/MR: history, current state, and technologyBritish Journal of Radiology · 2026
- [18F]FDG brain PET-MR versus PET/CT in a clinical cohort: intra-subject quantitative comparisonsScientific Reports · 2026
- MRI-to-PET synthesis in breast cancer using Pix2Pix: validation with simultaneously acquired PET/MR and lesion-level quantitative assessmentEJNMMI Physics · 2026
- Improved 2.5D-UNet pseudo-CT generation for attenuation correction in PET imaging using 18F-fluorodeoxyglucose and 11C-acetoacetate radiotracers.EJNMMI physics · 2026
- Test-Retest Repeatability of [18F]FDG Uptake by Solid Tumors on PET/MRI: A Prospective, Multicenter Study Using the QIBA Protocol.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026