3D-printed patient-specific instrumentation significantly improves the accuracy of prosthesis alignment in unicompartmental knee arthroplasty: a retrospective study.
Kun Zhang, Jinhua Zhang, Shang Gao, Zhuoli Li, Na Shen, Xiangyu Meng, Peng Sun
Department of Trauma Orthopedics, Shenzhen Longhua District People's Hospital, Shenzhen, Guangdong Province, 518100, China. · The 970th Hospital of the Joint Logistics Support Force of PLA, No. 7, Zhichu South Road, Zhifu District, Yantai, Shandong Province, 264002, China.
Key points
From the paper's conclusion- 3D-printed PSI significantly enhances the accuracy of prosthesis positioning in UKA, reduces operative time, and lowers the learning curve for less-experienced surgeons. Its core value lies in translating complex biomechanical requirements into standardized, executable surgical plans, thereby minimizing outliers in key alignment parameters.
Abstract
BACKGROUND: Unicompartmental knee arthroplasty (UKA) is an effective treatment for medial compartment knee osteoarthritis, with its outcomes highly dependent on the accuracy of prosthesis positioning. Conventional UKA, performed using traditional instrumentation, often relies heavily on surgical experience and may lead to variability in alignment. The emergence of 3D-printed patient-specific instrumentation (PSI) offers a promising approach to improve prosthesis placement accuracy and operational reproducibility. This study aims to evaluate the postoperative prosthesis position and short-term clinical outcomes of UKA assisted by 3D-printed PSI. METHODS: A retrospective analysis was conducted on 22 patients (25 knees) who underwent PSI-guided UKA between May 2023 and May 2024. These were compared with 25 patients (31 knees) undergoing conventional UKA during the same period. Postoperative radiographic assessments included prosthesis position, limb alignment, and range of motion (ROM) in the sagittal plane. Clinical outcomes were evaluated using functional scores. RESULTS: Both groups showed significant improvement in limb alignment and knee function postoperatively (p < 0.05), with no significant difference in preoperative and postoperative FTA within or between groups. The PSI group demonstrated superior outcomes in AKS-K score (91.7 ± 8.2 vs. 85.5 ± 6.9) and ROM (128.6° ± 9.4° vs. 120.3° ± 7.4°) compared to the control group (p < 0.05). Prosthesis positioning was significantly more accurate in the PSI group regarding coronal and sagittal alignment of both tibial and femoral components (p < 0.05). No significant difference was found in joint line height restoration. CONCLUSION: 3D-printed PSI significantly enhances the accuracy of prosthesis positioning in UKA, reduces operative time, and lowers the learning curve for less-experienced surgeons. Its core value lies in translating complex biomechanical requirements into standardized, executable surgical plans, thereby minimizing outliers in key alignment parameters.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Functional outcomes of patient-specific instrumentation versus conventional instrumentation for unicompartmental knee replacement: A systematic review and meta-analysis.The Knee · 2026
- Manual Instrumentation Is Associated With Greater Precision Than Patient-Specific Instrumentation For Initial Tibial Resections In Unrestricted Kinematic Alignment Total Knee Arthroplasty: A Comparative Cohort Study.Orthopaedics & traumatology, surgery & research : OTSR · 2026
- Suspended patient-specific instrument-assisted femur-first osteotomy for fixed-bearing unicompartmental knee arthroplasty: technical note and preliminary clinical results.Journal of orthopaedic surgery and research · 2026
- Radiographic accuracy of implant positioning in unicompartmental knee arthroplasty, does an imageless robotic system make a difference?Archives of orthopaedic and trauma surgery · 2026
- Current Reviews in Musculoskeletal Medicine Innovative Techniques in Knee Preservation: Osteotomy about the Knee: The Advent of Patient Specific Instrumentation (PSI).Current reviews in musculoskeletal medicine · 2026
- A prospective double-blinded randomized controlled trial comparing conventional jig-based versus robotic arm-assisted medial unicompartmental knee arthroplasty.The bone & joint journal · 2026