Current Reviews in Musculoskeletal Medicine Innovative Techniques in Knee Preservation: Osteotomy about the Knee: The Advent of Patient Specific Instrumentation (PSI).
Bradley A Lezak, Michael J Alaia
NYU Langone Orthopedic Center, 333 East 38th Street, 4th Floor, New York, NY, 10014, USA. · NYU Langone Orthopedic Center, 333 East 38th Street, 4th Floor, New York, NY, 10014, USA. Michael.Alaia@nyulangone.org.
Key points
From the paper's conclusion- A 2026 meta-analysis found PSI-guided high tibial osteotomy required fewer fluoroscopic images and was about 20 min shorter than conventional technique, with no difference in complication risk.
Abstract
PURPOSE OF REVIEW: Osteotomy about the knee corrects lower extremity malalignment to unload the diseased compartment or for combined procedures to optimize outcomes. Planning from 2D radiographs and freehand execution can leave a gap between planned and achieved correction. Patient-specific instrumentation (PSI) uses CT- or MRI-derived 3D models to produce custom cutting guides and plates that carry the preoperative plan into the operating room. This review summarizes the evidence on PSI for osteotomy about the knee, covering accuracy, safety, versatility, efficiency, and patient-reported outcomes. RECENT FINDINGS: PSI reproduces planned coronal and sagittal corrections to within about 1°, and comparative studies and meta-analyses show improved accuracy and fewer outliers compared with conventional technique, though some studies find no advantage in experienced hands. A 2026 meta-analysis found PSI-guided high tibial osteotomy required fewer fluoroscopic images and was about 20 min shorter than conventional technique, with no difference in complication risk. These gains appear after roughly 10 cases. PSI allows a single guide to correct coronal alignment and posterior tibial slope together and supports double-level osteotomy and concomitant ligament or meniscal procedures. Patient-reported outcomes improve with either PSI or conventional technique; PSI shows an early advantage at 3 to 6 months that is gone by final follow-up. PSI improves the accuracy and efficiency of knee osteotomy and reduces radiation exposure, with complication rates similar to conventional technique. Its greatest value is in complex multiplanar and slope-correcting osteotomies, combined procedures, and for surgeons earlier in their osteotomy experience. Cost, manufacturing lead time, guide-related soft-tissue exposure, and the lack of long-term outcome data remain limitations. Prospective studies with longer follow-up are needed to determine whether PSI's technical precision produces more durable clinical results.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Patient-Specific Instrumentation for Medial Opening Wedge High Tibial Osteotomy With Concomitant Medial Meniscal Root Repair.Video journal of sports medicine · 2026
- 3D-CT-guided patient-specific instrumentation versus conventional implants for traumatic malunited distal radius corrective osteotomies: A systematic review and meta-analysis.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
- Functional outcomes of patient-specific instrumentation versus conventional instrumentation for unicompartmental knee replacement: A systematic review and meta-analysis.The Knee · 2026
- Artificial intelligence-assisted three-dimensional preoperative planning with patient-specific cutting guides versus conventional planning and instrumentation in total knee arthroplasty: a prospective exploratory cohort study.Journal of orthopaedic surgery and research · 2026
- Accuracy of β-tricalcium phosphate gap patient-specific implants in chin osteotomies: a pilot validation study.International journal of oral and maxillofacial surgery · 2026
- 3D-printed patient-specific instrumentation significantly improves the accuracy of prosthesis alignment in unicompartmental knee arthroplasty: a retrospective study.3D printing in medicine · 2026