Reliability, Device Agreement and Validity of Load-Velocity Profiles: A Systematic Review with Meta-analysis.
Nina Claassen, Stanislav Dimitri Siegel, Mareike Sproll, Niklas Lebelt, Alyssa Virginia Bargende, Anne Marieke Fasold, Konstantin Warneke
Institute of Human Movement Science and Exercise Physiology, University Osnabrück, Osnabrück, Germany. · Institute of Human Movement Science and Exercise Physiology, Friedrich Schiller University Jena, Jena, Germany.
Key points
From the paper's conclusion- Therefore, velocity-based monitoring and 1RM prediction require cautious interpretation, as sensor- and exercise-specific evidence remains limited.
Abstract
BACKGROUND: For a valid one-repetition maximum (1RM) prediction via load-velocity (LV) relationships, high reliability and accuracy must be assumed. OBJECTIVE: Since individual study results indicate ambivalent prediction, this systematic review and meta-analysis was designed to provide a updated and comprehensive overview, extending knowledge about the validity and reliability of commercially available velocity sensors in Part I and the validity and reliability of velocity-based 1RM prediction models in Part II. METHODS: A systematic literature search was conducted in PubMed/MEDLINE, Web of Science, and Scopus. Validity and/or reliability studies or velocity-based 1RM prediction evaluations were included. Methodological quality was assessed using adapted COSMIN. The analysis was performed for intraclass correlation coefficient (ICC), Lin's concordance correlation coefficient (CCC), and Pearson's correlation coefficient (r). The review was preregistered in PROSPERO (CRD42025634595). RESULTS: Sixty-three studies were included for sensor validity and reliability and 38 for 1RM prediction models. Part I: Velocity sensors demonstrated good-to-excellent pooled validity and device agreement (ICC = 0.91-0.92 [0.83-0.97]; k = 55 and 439, respectively); intra- and inter-day reliability were classified as good to excellent with ICC = 0.90-0.91 [0.85-0.95] (k = 228 and 608, respectively), with sensor technology moderating the results. However, substantial heterogeneity and wide ranges of study-level estimates indicated considerable variability across moderators, linear position transducer (LPT) generally showing more consistent performance than inertial measurement units (IMU). Part II: Velocity-based 1RM prediction showed ICCs = 0.90 [0.83-0.94] (k = 124) and ICC = 0.91 [0.72-0.98] (k = 9); for reliability and validity, respectively. DISCUSSION: Commercial velocity sensors generally provide high relative validity and reliability. Results varied depending on exercise complexity, intensity, sensor technology, and modeling approach. While velocity-based 1RM prediction demonstrated high average validity, large heterogeneity in lower body exercises significantly biased the results. Furthermore, the dearth of measurement error and agreement analyses prohibits final conclusions. CONCLUSION: Therefore, velocity-based monitoring and 1RM prediction require cautious interpretation, as sensor- and exercise-specific evidence remains limited.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Practical Approach to Assess the Load-Velocity Profile in Sprint Swimming: Reliability of a Portable Resistance Device.Journal of strength and conditioning research · 2026
- Predicting the Free‐Weight Back Squat 1‐Repetition Maximum: Comparing Regression Models and Minimum Velocity Thresholds Across SexesEuropean Journal of Sport Science · 2026
- Reliability of Sprint Time and Force-Velocity Profiles During Sprint Acceleration in Elite Rugby Union Players: Inter-Trial Reliability of Linear Encoder, GPS, Timing Gates and Video Analysis.Sports (Basel, Switzerland) · 2026
- Velocity-Based Monitoring Lacks Both Accuracy and Applicability for Estimating Repetitions in Reserve During the Hexagonal Bar DeadliftThe Journal of Strength and Conditioning Research · 2026
- Comparing Repetition-Velocity Output from a Motor-Integrated Magnetic Sensing System with That of a Linear Position Transducer Across Resistance Exercises and Loads: A Human Trial Experiment.Sensors (Basel, Switzerland) · 2026
- Concurrent Validity and Within-Session Reliability of a Wireless Surface Electromyography Device (MR EMG) Compared to a Criterion Measure During the Leg Extension Exercise.Sensors (Basel, Switzerland) · 2026