Comparing Repetition-Velocity Output from a Motor-Integrated Magnetic Sensing System with That of a Linear Position Transducer Across Resistance Exercises and Loads: A Human Trial Experiment.
Alchan Kim
Department of Sports & Technology, Seokyeong University, 124 Seogyeong-ro, Seongbuk-gu, Seoul 02713, Republic of Korea.
Key points
From the paper's conclusion- Mean bias did not differ significantly by exercise, load, or their interaction, whereas proportional bias was significant (β = 0.125, p < 0.001).
Abstract
Equipment with integrated sensing can now provide repetition-velocity feedback without external sensors. However, whether their output agrees with that of established commercial linear position transducers has yet to be investigated. This study addresses this gap by comparing repetition-velocity measurements obtained from the motor-integrated magnetic sensing system of MOTY V with those obtained from GymAware RS to evaluate inter-device agreement and measurement characteristics. Deadlifts and squats were performed at 40%, 60%, and 80% of estimated one-repetition maximum by 15 male students, with both devices simultaneously measuring bar movement. The final analysis included 897 paired repetitions out of 900 planned pairs. Mean velocities were 0.7102 ± 0.1496 m/s for MOTY V and 0.6816 ± 0.1410 m/s for GymAware RS. The mixed-effects mean bias (MOTY V-GymAware RS) was 0.0285 m/s (95% confidence interval [CI], 0.0216-0.0353), with repeated-measures 95% limits of agreement ranging from -0.0773 to +0.1342 m/s. Mean absolute error and root mean square error were 0.0467 and 0.0609 m/s, respectively. Repetition-level correlation was r = 0.933, and set-level absolute-agreement intraclass correlation coefficient (ICC) was 0.958 (95% CI, 0.929-0.973). Mean bias did not differ significantly by exercise, load, or their interaction, whereas proportional bias was significant (β = 0.125, p < 0.001). MOTY V showed high agreement with GymAware RS, but small positive systematic and proportional biases preclude assuming direct interchangeability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of video-based event detection against laboratory-standard biomechanical measures: a synchronized multimodal study.Frontiers in bioengineering and biotechnology · 2026
- Measurement Uncertainty and Traceability in Upper Limb Rehabilitation Robotics: A Metrology-Oriented ReviewJournal of Sensor and Actuator Networks · 2026
- A High‐Precision Triboelectric Rotational Sensor for Enhanced Low‐Speed Monitoring via Magnetic Modulation in Smart Fitness SystemsSmartSys · 2025
- A scalable, hyperstable intelligent fibre velocimeter for dynamic digitization of resistance trainingNational Science Review · 2025
- Concurrent Validity and Within-Session Reliability of a Wireless Surface Electromyography Device (MR EMG) Compared to a Criterion Measure During the Leg Extension Exercise.Sensors (Basel, Switzerland) · 2026
- Agreement between and test-retest reliability within Theia3D markerless and Vicon marker-based three-dimensional motion capture systems during barbell back squats in trained lifters.Journal of sports sciences · 2026