Key points
From the paper's conclusion- The proposed 2.5D UNet, using adjacent PET image slices for added context, outperforms the 2D UNet in generating accurate pseudo-CTs from NAC PET images, enabling effective and fast attenuation correction without additional radiation or imaging.
Abstract
BACKGROUND: Attenuation in PET imaging can lead to quantification errors, underestimation of lesions and misinterpretation of the extent of disease. Commonly, this correction is made using a CT image that provides additional anatomical information. Unfortunately, using CT significantly increases the radiation dose received by patients, increases the cost of imaging equipment, and can cause misregistration errors. To overcome these limitations, deep-learning based methods were proposed to generate a pseudo-CT from the non-attenuation-corrected (NAC) PET image, which can then be used to correct for attenuation. METHODS: In this work, an improved UNet 2.5D architecture has been developed in which three consecutive PET image slices are used to provide more contextual information to generate a single CT slice. A dataset of 189 NAC head PET scans from patients injected with F-fluorodeoxyglucose or C-acetoacetate, and the corresponding CT images were used for training. RESULTS: The generated pseudo-CT of all patients showed an overall improvement with the proposed UNet 2.5D architecture. Compared to a standard UNet 2D architecture, the soft tissue dice score increased from (0.905 ± 0.015) to (0.922 ± 0.017), along with the SSIM score increasing from (0.889 ± 0.023) to (0.921 ± 0.019). 3D forward projections comparing the CT and pseudo-CT total attenuation projection values also highlight the improved attenuation maps generated by the proposed 2.5D deep learning architecture. CONCLUSION: The proposed 2.5D UNet, using adjacent PET image slices for added context, outperforms the 2D UNet in generating accurate pseudo-CTs from NAC PET images, enabling effective and fast attenuation correction without additional radiation or imaging.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deep learning-based approaches for attenuation correction in [18F]FDG PET: Current advances and future directions.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- A two-stage PET/MRI attenuation-correction workflow for pseudo-CT and AC PET synthesis with GUI-based inference.Medical & biological engineering & computing · 2026
- A rapid total-body PET imaging approach for pediatric patients using non-attenuation-corrected PET scansEJNMMI Physics · 2026
- Characterization of parotid lesions with dual-energy CT: Can virtual unenhanced images permit selective omission of true unenhanced acquisition?European journal of radiology · 2026
- Deep learning for CT-less attenuation correction synthesis in non-small cell lung cancer: A proof-of-concept evaluated for quantitative and physical characteristics.Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2026
- Image-Condition-Controlled Diffusion Network with Large-Scale CT Pretraining for CT-Free Attenuation Correction in Dynamic Cardiac PETarXiv · 2026