Image-Condition-Controlled Diffusion Network with Large-Scale CT Pretraining for CT-Free Attenuation Correction in Dynamic Cardiac PET
Zhejia Zhang, Scott M. Leonard, Jinkui Hao, Ryan J. Avery, Richard L. Weinberg, Bo Zhou
Key points
From the paper's conclusion- We evaluated LUCID on an in-house dataset of 102 patients and found that it achieved the best quantitative accuracy while maintaining competitive inter-frame consistency.
Abstract
Positron emission tomography (PET) provides quantitative information on myocardial perfusion. In dynamic PET, tracer kinetics are tracked through a series of reconstructed time frames. Reliable attenuation correction is essential for accurate measurements. Clinical attenuation maps ($\mu$-maps) are typically derived from computed tomography (CT), which adds radiation exposure and may introduce PET-CT misregistration due to respiratory and cardiac motion. Moreover, supervised CT-free methods rely on paired non-attenuation-corrected (NAC) PET and CT data, which are scarce, whereas large-scale unpaired CT data are more readily available. To address these challenges, we propose Large-scale Unpaired CT-Informed Diffusion (LUCID), a framework that transfers anatomical priors learned from 10,000 chest CT volumes in the public CT-RATE dataset to $\mu$-map synthesis for dynamic cardiac $^{82}$Rb PET. First, a convolutional neural network (CNN) predicts an initial $\mu$-map from each NAC PET frame. Second, the CT-pretrained diffusion backbone refines a low-noise perturbation of the CNN prediction through a single denoising step, conditioned on the corresponding NAC PET frame via ControlNet. Finally, frame-wise predictions are averaged voxel-wise to obtain the final $\mu$-map. We further introduce the voxel-wise temporal standard deviation (TSD) to quantify inter-frame variability without requiring a reference $\mu$-map. We evaluated LUCID on an in-house dataset of 102 patients and found that it achieved the best quantitative accuracy while maintaining competitive inter-frame consistency. Ablation studies showed that refinement with a diffusion backbone pretrained on in-house CT data from the training patients was less accurate than the CNN prediction alone, highlighting the importance of large-scale CT pretraining.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- DiffCAS: Inference-time CT-free diffusion model for physics-aware multi-slice attenuation correction in cardiac SPECT.Artificial intelligence in medicine · 2026
- AnF-DiffPET: anatomy- and frequency-guided diffusion for simulated low-dose PET/CT denoising.Physics in medicine and biology · 2026
- PET Image Reconstruction Using Deep Diffusion Image PriorIEEE Transactions on Medical Imaging · 2026
- Count-aware diffusion with autoregressive inference for low-count PET reconstruction enhancement.Medical image analysis · 2026
- Per-Bundle, Pre-Reconstruction Inversion for Temporal CT: Flux-Compensation Design and Multi-Patient GeneralizationarXiv · 2026
- MedicalDPO: Multi-Objective Direct Preference Optimization for CT to PET TranslationarXiv · 2026