RapidArc dynamic versus IMRT and VMAT for endometrial cancer SIB radiotherapy.
Yutong Zhao, Xinqiang Zhang, Xiaoshen Wang, Zejun Jiang, Xingmin Ma, Jing Liu, Haonan Xiao, Guanzhong Gong,
Shandong Cancer Hospital and Institute, Shandong First Medical University, Shandong Academy of Medical Science, No. 440, Jiyan Road, Shandong Province, Jinan, China. · Clinical Application Department, Varian Medical System, Beijing, China.
Key points
From the paper's conclusion- It represents a promising technique for endometrial SIB radiotherapy, combining the advantages of IMRT and VMAT.
Abstract
BACKGROUND: Radiotherapy with simultaneous integrated boost (SIB) for endometrial cancer requires highly conformal dose distributions to reduce toxicity. RapidArc Dynamic (RAD), a novel technique combining dynamic arc delivery with strategic gantry pauses, may improve organ-at-risk (OAR) sparing. PURPOSE: This study aimed to compare RAD with conventional IMRT and VMAT for endometrial SIB radiotherapy, specifically evaluating the OAR sparing capabilities of the RAD technique in endometrial cancer treatment. MATERIALS AND METHODS: Thirty patients with high-intermediate risk endometrial cancer were retrospectively enrolled. Three plans (RAD, IMRT, VMAT) were generated per patient, prescribing 50.4 Gy to the planning target volume (PTV) and 61.6 Gy to the nodal clinical target volume (CTVn) in 28 fractions. Plans were evaluated for OAR dose constraints, conformity index (CI), 50% dose spillage ratio , monitor units (MU), and modulation complexity score (MCS). RESULTS: RAD plans demonstrated superior OAR sparing, with fewer and less severe constraint violations for the bladder, rectum, small intestine, and bone marrow compared to IMRT and VMAT (Mann-Whitney U test, P < 0.05). RAD achieved a significantly higher average CI (0.833) than two-arc VMAT (0.813) and demonstrated the lowest average (3.45) compared to both IMRT (3.86) and VMAT (3.67). Furthermore, while VMAT required the fewest MU (527.8), RAD (1314.7) used significantly fewer MU than IMRT (3334.0) and exhibited higher MCS, indicating less complex delivery than IMRT. CONCLUSIONS: RAD provides superior OAR protection and steeper dose fall-offs compared to VMAT, while maintaining high target dose conformity and potentially improving delivery efficiency. It represents a promising technique for endometrial SIB radiotherapy, combining the advantages of IMRT and VMAT. CLINICAL TRIAL NUMBER: Not applicable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of 3D-CRT vs. VMAT for radiotherapy of whole breast with simultaneous integrated boostActa Oncologica · 2026
- Dosimetric Comparison of Five Radiotherapy Techniques in Left-Sided Breast Cancer Patients Following Breast-Conserving Surgery.The breast journal · 2026
- Comparative Analysis of Arc Geometrical Configurations and Jaw Tracking for Peripheral Low-Dose Bath in Whole Breast VMAT.Technology in cancer research & treatment · 2026
- MR-based vaginal vault brachytherapy in endometrial cancer: a dosimetric studyPathology & Oncology Research · 2026
- Dosimetric Comparison of One-, Two-, Three-, and Four-Arc Volumetric Modulated Arc Therapy Plans in Cervical Carcinoma: Evaluation of Plan Quality, Organ-at-Risk Sparing, and Treatment Efficiency.Cureus · 2026
- Strategic planning approaches to optimize volumetric modulated arc therapy for locoregional breast irradiation.Radiation and environmental biophysics · 2026