Efficacy of non-invasive mechanical ventilation to reduce organ motion for abdominal radiotherapy.

Jorrit Visser, Johannes K Veldman, Michael J Parkes, Markus F Stevens, Joost G van den Aardweg, Eva Versteijne, Arjan Bel, Irma W E M van Dijk,

Department of Radiotherapy, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands. jorrit.visser@amsterdamumc.nl. · Department of Radiotherapy, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands.

Key points

From the paper's conclusion
  • Regularized breathing imposed by NIMV reduces organ motion considerably and, is therefore, an effective respiratory motion mitigation strategy for abdominal organ radiotherapy.

Abstract

BACKGROUND: Respiratory motion is a challenge in abdominal radiotherapy. Motion mitigation strategies include gating or tracking, abdominal compression and breath-holding. With non-invasive mechanical ventilation (NIMV) regular breathing patterns can be imposed at typically 30 or 60 breaths per minute (brpm). NIMV at these high frequencies and with smaller tidal volumes reduce respiratory motion. Adding positive end-expiratory pressure (PEEP) to this regularized breathing also adds the advantage of increasing lung volume. The aim of this study was to compare respiratory motion of abdominal organs between free breathing and regularized breathing in volunteers. METHODS: In two sessions on different days ten healthy volunteers were imaged during free breathing (FB), NIMV-imposed regularized breathing at a frequency of 30 (NIMV30) and 60 brpm with PEEP (NIMV60P). Alternating single-slice coronal and sagittal MR images were acquired with a frequency of 2.7 Hz during a period of 350 s. On a single image at mid-ventilation the liver, spleen and kidneys were delineated, if visible. Other images were deformably registered to this reference image, resulting in a deformation vector field for each image. Vector fields were used to determine the motion in each voxel of the reference image after excluding 5% outliers. For voxels in each organ a histogram of the motion was calculated. The motion of the voxels at the 10th percentile, median and 90th percentile was used to represent the motion of the organ. Organ motion was compared between FB and NIMV. RESULTS: Sixty MRI scans were available for this study. For all organs, the caudal-cranial (CC) motion was significantly smaller during NIMV30 and NIMV60P compared to FB. The group median CC motion of the liver was 29 mm, 16 mm and 9 mm for FB, NIMV30 and NIMV60P, respectively; for the spleen 31 mm, 20 mm, 12 mm; for the right kidney 22 mm, 14 mm and 9 mm; for the left kidney 19 mm, 14 mm and 10 mm. CONCLUSIONS: Regularized breathing imposed by NIMV reduces organ motion considerably and, is therefore, an effective respiratory motion mitigation strategy for abdominal organ radiotherapy. TRIAL REGISTRATION: The study is registered in the ICTRP; NL-OMON24117. The registration date was March 29, 2021.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers