Teaching organ-at-risk delineation in the AI era: educational impact and dosimetric relevance of a structured training intervention
William Gehin, S. Huger, N. Grandgirard, J.-C. Faivre, Marie Bruand, Nicolas Martz, C. Charra-Brunaud, Julia Salleron,
Institut de Cancérologie de Lorraine
Key points
From the paper's conclusion- These findings are exploratory and, in the absence of a control group and with residents reassessed on the same case, should be interpreted as associations rather than as a demonstrated causal effect.
Abstract
Accurate delineation of organs at risk (OARs) remains a cornerstone of radiotherapy planning. As AI-assisted auto-contouring enters routine practice, the place of contouring in residency training is increasingly debated: should residents still be trained to contour, and if so, with what focus? To evaluate the impact of a structured educational intervention on OAR contouring accuracy among radiation oncology residents, and to assess whether training-related changes in contouring performance are reflected in geometric and dosimetric endpoints, with an independent commercial AI auto-segmentation system used as a descriptive benchmark. In this exploratory single-institution study, ten residents independently contoured OARs on a left breast and regional nodal irradiation case before and seven weeks after a two-hour targeted teaching session, with an eight-week interval between sessions and no control group. Expert-validated reference contours were defined by a senior radiation oncologist following routine clinical practice, consisting of expert review and correction of AI-assisted auto-segmentation outputs (MVision AI™ v1.2.7). For contextual benchmarking, an additional commercial AI auto-segmentation system (RayStation ® v23B) was evaluated descriptively. Geometric accuracy was assessed using the Dice Similarity Coefficient (DSC) and the 95th-percentile Hausdorff Distance (HD95). To assess dosimetric relevance, the same fixed VMAT dose distribution was applied to each contour set, and dose–volume metrics were recalculated without re-optimisation, so that the analysis reflects the effect of contour variation on reported dose–volume values rather than on delivered dose. Training was associated with a significant overall improvement in contouring accuracy in mixed-effects analysis (DSC β = +0.034, 95% CI [+ 0.017 ; +0.052], p < 0.001; HD95 geometric ratio 0.788, 95% CI [0.694 ; 0.896], p < 0.001, i.e. a 21.2% reduction). Exploratory structure-specific analyses showed the largest effects for the brachial plexuses (DSC, rank-biserial r = + 0.93 and + 0.82) and for the left anterior descending coronary artery (HD95, r = + 0.85), although no structure-specific comparison remained significant after adjustment for multiple testing. Dosimetric differences were small, none remained significant after adjustment, and overall compliance with mandatory constraints did not change significantly. Post-training accuracy was broadly comparable to that of the evaluated commercial auto-segmentation system, which performed less well for the small tubular structure available for comparison. A short, structured teaching session was associated with improved OAR contouring accuracy, with the largest changes observed for anatomically complex structures. These findings are exploratory and, in the absence of a control group and with residents reassessed on the same case, should be interpreted as associations rather than as a demonstrated causal effect. The observed changes are potentially relevant to plan evaluation rather than demonstrably clinically meaningful. As automated segmentation becomes routine, whether the ability to critically appraise and correct AI-generated contours requires dedicated instruction, or develops from conventional contouring training, remains an open question that this study was not designed to address.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Organ-at-risk contouring education in the era of AI-assisted practice: Insights from an Australian undergraduate radiation therapy program.Journal of medical imaging and radiation sciences · 2026
- Performances of AI-based automatic delineation of CTV and Organs-at-Risk for breast radiotherapy planning: including inter-observer variability in the evaluation process.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Clinical validation of AI‐assisted contouring in prostate radiation therapy treatment planning: Highlighting automation bias and the need for standardized quality assuranceJournal of Applied Clinical Medical Physics · 2025
- A prospective randomized evaluation of AI assisted GTV contouring in head-and-neck radiotherapy.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2026
- Next-Generation Segmentation in Radiotherapy: A Narrative Review from Atlas-Based Methods to Agentic Vision-Language ModelsarXiv · 2026
- AI-Assisted Contour Quality Assurance in a Multi-Center Genitourinary Clinical Trial: Feasibility Results from NRG-GU010.International journal of radiation oncology, biology, physics · 2026