AI-Assisted Contour Quality Assurance in a Multi-Center Genitourinary Clinical Trial: Feasibility Results from NRG-GU010.
Huaizhi Geng, Theodore Karrison, Neil B Desai, Alejandro Berlin, Zachary S Zumsteg, Brian Baumann, Joanne C Hunter, Grant Richard Seeger,
University of Pennsylvania, Philadelphia, PA. Electronic address: huaizhigeng@pennmedicine.upenn.edu. · NRG Oncology Statistics and Data Management Center, Philadelphia, PA, USA; University of Chicago Comprehensive Cancer Center, Chicago, IL.
Key points
From the paper's conclusion- AI-assisted contour comparison served as a high-sensitivity triage tool, flagging all clinically unacceptable deviations while clearing AI-negative cases, supporting its use as a screening aid-not a replacement-for expert contour QA in GU clinical trials. Lower specificity (particularly for OARs) and few score-3 events warrant further disease-site-specific validation.
Abstract
PURPOSE: Expert contour quality assurance (QA) in multi-center radiation therapy trials is labor-intensive and scales poorly. We evaluated whether an FDA-cleared AI auto-segmentation tool can serve as a high-sensitivity screening aid for contour QA in the genitourinary (GU) trial NRG-GU010. METHODS AND MATERIALS: Data from 579 patients submitted to NRG-GU010 (NCT05050084) were studied in two cohorts: the first 52 consecutive submissions (one excluded for an unavailable planning CT; 51 analyzed) for a consensus-based agreement analysis, and the subsequent 527 for large-cohort workflow validation. AI-generated contours were compared with submitted contours using four geometric indices (Dice similarity, Hausdorff distance, mean distance to agreement, percent volume change) against thresholds from prior per-protocol cases, producing target-volume (TV) and organ-at-risk (OAR) scores of 1 (per-protocol), 2 (acceptable variation), or 3 (unacceptable deviation). The 51-case cohort used multi-expert adjudicated consensus as reference; the 527-case cohort used each case's single reviewing principal investigator (PI) under a triage framework (AI-positive = score 2 or 3; PI-positive = score 3). Agreement was assessed with quadratic-weighted Cohen's kappa; sensitivity and specificity are reported with 95% confidence intervals (CIs). RESULTS: In the consensus cohort, AI identified all four unacceptable (score-3) OAR deviations (sensitivity 1.00; 95% CI, 0.40-1.00); no consensus score-3 TV cases were present. Quadratic-weighted kappa was 0.71 (0.40-0.90) for OAR and 0.53 (0.31-0.74) for TV. In the 527-case validation cohort, AI triage sensitivity was 100% for both TV (5/5) and OAR (4/4) score-3 deviations, with case-level specificity of 69% (TV) and 25% (OAR) and 100% negative predictive value for both. CONCLUSIONS: AI-assisted contour comparison served as a high-sensitivity triage tool, flagging all clinically unacceptable deviations while clearing AI-negative cases, supporting its use as a screening aid-not a replacement-for expert contour QA in GU clinical trials. Lower specificity (particularly for OARs) and few score-3 events warrant further disease-site-specific validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical validation of AI‐assisted contouring in prostate radiation therapy treatment planning: Highlighting automation bias and the need for standardized quality assuranceJournal of Applied Clinical Medical Physics · 2025
- A prospective randomized evaluation of AI assisted GTV contouring in head-and-neck radiotherapy.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2026
- Defining an evaluation framework for radiotherapy trials which use artificial intelligence- lessons from the ARCHERY trialFrontiers in Oncology · 2026
- Teaching organ-at-risk delineation in the AI era: educational impact and dosimetric relevance of a structured training interventionBMC Medical Education · 2026
- Performances of AI-based automatic delineation of CTV and Organs-at-Risk for breast radiotherapy planning: including inter-observer variability in the evaluation process.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Organ-at-risk contouring education in the era of AI-assisted practice: Insights from an Australian undergraduate radiation therapy program.Journal of medical imaging and radiation sciences · 2026