Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology

A prospective randomized evaluation of AI assisted GTV contouring in head-and-neck radiotherapy.

Mathis E Rasmussen, Jintao Ren, Jasper A Nijkamp, Anne I S Holm, Kristoffer Moos, Kim M Hochreuter, Hanne Primdahl, Christian Nicolaj Andreassen,

Danish Center for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; Department of Experimental Clinical Oncology, Aarhus University Hospital, Aarhus, Denmark. · Danish Center for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.

Randomised · n=85

Key points

From the paper's conclusion
  • The median difference in APL between groups was consistent with no relevant effect for GTV-T. For GTV-N, however, AI-assisted contouring tended towards more editing during peer review for APL, but not for supplementary contour metrics. No efficiency benefits were demonstrated. Overall, these findings do not indicate a concern, but warrants further research before widespread adoption.

Abstract

BACKGROUND: AI-assisted contouring has demonstrated efficiency and consistency benefits for organs-at-risk in radiotherapy. However, its impact on gross tumor volume (GTV) delineation remains unexplored. The aim of this study was to evaluate AI-assisted GTV contouring in head and neck cancer radiotherapy in an exploratory randomized controlled clinical trial. METHODS: In this prospective, single-centre, randomized controlled evaluation, patients referred for curative-intent radiotherapy of head-neck cancer were randomized to manual contouring (control) or AI-assisted contouring (intervention) of gross tumor volumes using an in-house developed segmentation model. The primary endpoint was the extent of editing during a blinded multidisciplinary target conference, using normalized Added Path Length (APL). Secondary endpoints included conference duration, self-reported contouring time, and perceived complexity of the cases. RESULTS: Between Sept 11, 2023, and Jan 20, 2025, 85 patients were enrolled; 83 were included in the analysis (41 control, 42 AI-assisted). The median difference in APL (AI-assisted minus control, negative favoring the intervention) was -0.02 [-0.32; 0.07] for GTV-T and 0.06 [-0.01; 0.14] for GTV-N. Conference duration, contouring time, and perceived complexity were similar between groups. No adverse events were reported. CONCLUSION: The median difference in APL between groups was consistent with no relevant effect for GTV-T. For GTV-N, however, AI-assisted contouring tended towards more editing during peer review for APL, but not for supplementary contour metrics. No efficiency benefits were demonstrated. Overall, these findings do not indicate a concern, but warrants further research before widespread adoption.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers