Digital orthodontic setup-based assessment of post-treatment open gingival embrasures in adult extraction cases with fixed appliances: a retrospective study
Xinyi Ren, Jiaxin Deng, Lang Lei, Jialing Li, Huang Li
Key points
From the paper's conclusion- The findings support feasibility rather than validated prediction or examiner-independent reproducibility; prospective external validation with independent examiners is required before clinical utility can be established.
Abstract
Background To evaluate agreement between assessments of post-treatment open gingival embrasure (OGE) presence and severity based on simulated three-dimensional gingival morphology in digital orthodontic setups and photographic reference classifications in adult extraction cases treated with fixed appliances. Methods This retrospective study included 62 adults treated with extraction of four first premolars and fixed appliances, each contributing 10 paired anterior interproximal sites (620 sites). A single examiner independent of patient treatment graded post-treatment photographs as the reference classification and the software-simulated three-dimensional gingival morphology in setups generated exclusively from pretreatment digital models. Overall linear weighted Cohen’s kappa (κ) for modified Jemt grades was the primary endpoint. Binary classification measures were secondary, and arch-, sex-, and site-stratified analyses were exploratory. All performance estimates were site-level; 95% confidence intervals (CIs) accounted for patient-level clustering. Results With 95% CIs in parentheses, overall linear weighted κ was 0.716 (0.657–0.769), exact-grade agreement was 0.808 (0.774–0.840), and mean absolute error was 0.194 (0.160–0.229) grades. Secondary binary accuracy was 0.918 (0.894–0.940), with sensitivity of 0.975 and specificity of 0.770. The photographic reference and setup-based proportions of OGE-positive sites were 71.9% and 76.6%, respectively, indicating a modest tendency toward setup-based overclassification (difference, 4.7% points). Conclusions Examiner-rated digital setup-based classifications showed preliminary within-sample agreement with post-treatment photographic reference classifications in this selected retrospective cohort. The findings support feasibility rather than validated prediction or examiner-independent reproducibility; prospective external validation with independent examiners is required before clinical utility can be established.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Peri-Implant Radiographic Measurements Compared With Intra-Surgical Assessments: Diagnostic Accuracy and Reproducibility.Journal of periodontal research · 2026
- Agreement Between Automated Cephalometric Analysis and Expert-Performed Manual Digital Tracing: A Comparative StudyDentistry Journal · 2026
- Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete-Arch Implant Prostheses: A Pilot Randomized Controlled Trial.Clinical oral implants research · 2026
- Diagnostic Accuracy and Reliability of Visual Assessment of Peri- Implant Keratinized Mucosa Width and Mucosal Thickness Using Digital Images.The International journal of periodontics & restorative dentistry · 2026
- Incidence of Open Gingival Embrasure During Orthodontic Treatment and Associated Factors: A Systematic Review.International journal of dentistry · 2026
- Post-treatment stability of anterior open bite treated with clear aligners in adults: a systematic review and meta-analysisBMC Oral Health · 2026